background image

 

5 HOMEDEPOT.COM

 

 

Please contact 1-877-527-0313 for further assistance.

Warranty Information

  

The manufacturer extends this warranty to the original retail purchaser of its model or, if this unit is purchased and installed by a building 
contractor, then to the original owner of the building. No subsequent purchaser of the unit or of a building which it is installed is entitled to 
any of the benefits of this warranty. 
This product is warranted against defects in materials and workmanship for a period of two (2) years from the date of original retail 
purchase. No other parts or components are warranted. There is no warranty for defects caused by abuse, faulty installation, or the like. 
Repairs or replacement parts supplied under this warranty are warranted only for the period of this warranty; that is, two (2) years from the 
date of the original retail purchase of the unit. 
In the event of a defect or malfunction, we will replace or repair the defective part or component only and return the new or repaired part to 
you freight prepaid. You must bear all other expenses incurred in obtaining repairs, including labor required for field repair or replacement, 
and the cost of shipping the defective part to us. You must also bear the cost of replacement of any part or component and the shipping 
charges incurred for the replacement and return to you any part or component not covered by this warranty, including parts or components 
damaged by you. 
The manufacturer reserves the right to demand and receive written evidence of the date of purchase before undertaking to perform its 
obligations under this warranty. You should, therefore, retain your sales slip. There is no informal dispute settling mechanism available in 
the event of a controversy involving this warranty. Any and all implied warranties which may exist terminate upon the expiration of this 
warranty, two (2) years from the date of the original retail purchase. Some states do not allow limitations on how long an implied warranty 
lasts, so this limitation may not apply to you. 
The manufacturer is not liable to you for incidental or consequential damages arising out of a defect or malfunction of a unit, or its 
installation, or out of any alleged breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential 
damages, so this limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which 
vary from state to state. 
Contact the Customer Service Team at 1-877-527-0313 or visit www.HomeDepot.com.

Содержание 3055 50 157

Страница 1: ...MacroAir Technologies 794 S Allen St San Bernardino CA 92408 NAME DATE COMMENTS Q A MFG APPR ENG APPR CHECKED DRAWN FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERAN...

Страница 2: ...g and user maintenance shall not be made by children without supervision HAZARD OF ELECTRIC SHOCK EXPLOSION OR ARC FLASH READ AND UNDERSTAND THIS MANUAL BEFORE INSTALLING OR OPERATING A FAN UNIT INSTA...

Страница 3: ...of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Contact the Customer Service Team at 1 877 527 0313 or visit...

Страница 4: ...n guy wires keep the fan stable in case of earthquakes or in outdoor installations where high wind conditions may occur MARK THE FLOOR TO ALERT PERSONNEL When mounting a fan in an area where materials...

Страница 5: ...ing the defective part to us You must also bear the cost of replacement of any part or component and the shipping charges incurred for the replacement and return to you any part or component not cover...

Страница 6: ...y covered in this Use and Care Guide please consult a structural engineer TOOLS REQUIRED Level Flat Blade Screwdriver Phillips Screwdriver 3 8 Combination Wrench 3 4 Combination Wrench 1 2 Combination...

Страница 7: ...s Nuts Washers 10 10 20 GG Safety Retainer Link 5 HH Guy Wire Clamps 8 SPACING REQUIREMENTS space from diffuser space from diffuser at least 1 5 x diameter away from intake discharge at least 2 x diam...

Страница 8: ...8 Part Description Quantity A Guy Wires 4 B Fan Blades 5 C Guy Wire Band 1 D Fan Motor Unit 1 E Mount 1 F Safety Cable 1 D C B A F E Pre Installation PACKAGE CONTENTS...

Страница 9: ...POT COM Please contact 1 877 527 0313 for further assistance FAN SPEED NEMA 4X IP65 Part Description Quantity A VFD Control Box 1 B Cable To The Incoming Power 1 C Cable To The Motor 1 C B A Pre Insta...

Страница 10: ...ount using two 2 I beam bolts and nuts with four 4 washers Hand tighten the bolts 2 Position the Top Plate Position the top plate under the I beam so that one side of the beam is between the clamp and...

Страница 11: ...D DRAWN FINISH MATERIAL INTERPRET GEOMETRIC TOLERANCING PER DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 010 ANGULAR MACH 1 BEND 1 TWO PLACE DECIMAL 01 THREE PLACE DECIMAL 001 PROPRIETARY AND CONFID...

Страница 12: ...CABLE THERE NEEDS TO BE A SMALL AMOUNT OF SLACK PRESENT IN THE SAFETY CABLE FOR PROPER FUNCTIONING AVOID SHARP EDGES Wrap the safety cable around the I beam 2 Secure the Safety Cable Clamps Secure tw...

Страница 13: ...WIRES NEED TO BE SECURELY MOUNTED TO THE BUILDING YOU CAN USE GENERIC BEAM CLAMPS WHEN MOUNTING TO I BEAM OR STEEL TRUSS LAG I BOLTS CAN BE USED WHEN MOUNTING TO WOOD GLULAMS DO NOT WRAP GUY WIRES AR...

Страница 14: ...gh one of the holes on the cable lock and then pull the end into the groove to lock it Use pliers to properly secure the cord in the groove of the cable lock 7 Repeat Step 6 Repeat step 6 for the seco...

Страница 15: ...IS NORMAL TO USE APPROXIMATELY HALF OF THE TUBE PER 5 STRUTS YOU DO NOT NEED TO USE THE WHOLE TUBE 2 Slide the Blades onto the Blade Struts Slide the blades onto the blade struts and align the holes...

Страница 16: ...able frequency drives VFDs are designed to be in compliance with regulatory agency limits for EMI However there is no guarantee that interference will not occur in a particular installation If Commerc...

Страница 17: ...ne end of the 50 cable to the motor through the top of the frame and plug it into the receptacle on the frame 2 Attach motor cable to VFD Attach the other end of the 50 cable to the receptacle on the...

Страница 18: ...tion 1 Turn the VFD on 2 Select forward direction for cooling or reverse for destratification heating 3 Adjust the speed dial to control how fast the fan rotates NEMA 4X IP65 FAN SPEED FAN SPEED NEMA...

Страница 19: ...he fan airfoils with a rag or sponge using hot water or regular cleaning solutions Please do not use chlorine or any chemicals containing chlorine Safety Cable Check Each fan comes with a safety cable...

Страница 20: ...the VFD are NOT lit Confirm the VFD is plugged into the wall and confirm that there is power coming from the building The fan is making a loud clicking noise Ensure that the anti seize was properly ap...

Страница 21: ...y Part Description Quantity A Complete Power Unit 1 I Retainer Links 1 B 15 Diameter Blade 78 1 J Retainer Links Set of 5 1 C 15 Diameter Blade Set of 5 78 1 K Mount Bolt Kit 1 D VFD 1 L Blade Bolt Ki...

Страница 22: ...roblems missing parts Before returning to the store call Commercial Electric Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 877 527 0313 HOMEDEPOT COM Retain this manual for...

Отзывы: