GE 800
Technical data
4.2/0617
33
Technical data
Intercom Server basic housing GE 800
Power supply card G8-GEN
Power supply card with programming jack, 2 relay outputs, 2 inputs for floating contacts, audio input,
power switch and signal LED for power supply.
AC power supply:
24 V (±5 %) / 80 VA
DC power supply:
24 – 35 V / 80 W
Emergency power consumption:
200 mAh/h for G8-GEN, G8-GEP, G8-GEB and G8-NET
for other cards, see technical data of the respective cards
Frequency range:
50 Hz to 15 kHz (–3 dB)
Total harmonic distortion:
less than 0.9%
Operating temperature range:
0 °C to +50 °C (32 °F to 122 °F)
Storage temperature range:
–30 °C to +60 °C (–22 °F to 140 °F)
Relative humidity:
20% up to 80 %, not condensing
Dimensions:
483 x 133 x 229 mm (19.03 x 5.24 x 9.02 in)
Weight incl. package:
approx. 5800 g (12.8 lbs)
Mounting:
19”, 3 HE
Relay outputs:
max. switching capacity: 60 W respectively 125 VA
max. switching current: 2 A
max. switching voltage 60 VDC / 40 VAC
Music input:
max. 800 mV
rms
at 10 kW, 16 kHz
Inputs IN1 and IN2:
for floating contacts, max. line resistance: 1.5 kW
Thermal dissipation loss:
(for calculation of the thermal load)
45.2 W
Operating temperature range:
0 °C to +50 °C (32 °F to 122 °F)
Storage temperature range:
–30 °C to +60 °C (–22 °F to 140 °F)
Relative humidity:
20% up to 80%, not condensing
Plug:
96-way PC board connector according DIN 41612
Emergency power consumption:
see GE 800 above
Dimensions:
100 x 167 mm (3.9 x 6.6 in)
Weight:
approx. 275 g (0.61 lbs)
Relay outputs:
type: change over contact
max. switching power: 60 W / 125 VA
max. switching current: 2 A
max. switching voltage: 60 VDC / 40 VAC
Inputs:
for floating contacts, max. line resistance: 1.5 kW
Music input:
max. 800 mV
rms
at 10 kW, 16 kHz