3. Assembly of components
GE 800
8
4.2/0617
3. Assembly of components
Pre-installed plug-in cards
The included plug-in cards G8-GEN, G8-GEP and G8-NET are pre-installed in the Intercom Server.
Plug-in positions of the cards
The plug-in cards can be inserted in the following slots:
ATTENTION: Exchanging cards
Cards may be exchanged only with voltage switched off!
Plug-in card
GEN
GEP
1
2
3
4
5
6
7
8
9
10 11 12 13 14
NET
max. per
housing
G8-16A
1)
14
G8-16E
14
G8-8E8A
1)
14
G8-CNET-E1
5
G8-LAN
7
G8-CNET-W
5
G8-AUD
14
G8-IAX
14
G8-IF
14
G8-IP
14
G8-IP-32
14
G8-TEL4
2)
2
G8-GED
14
G8-GEN
1
G8-GEP
1
G8-GET
14
G8-NET
1
G8-S0
7
G8-SELCALL
3)
4
G8-TEL
14
G8-V24-PRO
14
G8-VOIPSERV
6
1)
Max. 100 outputs may be switched on at the same time.
2)
For further information, see data sheet “
G8-TEL4
.”
3)
A second slot of the GE 800 is occupied by the G8-V24-PRO delivered with the G8-SELCALL.