b). If the vehicle is violated, the interior light will flash for the same duration as the siren.

 

H8/5. Black / Red wire – (-) 200mA Timer Control Channel 5 Output – 

(See Alarm Feature

 

III – 6

 Programming) 

(

Factory default setting

 on 

momentary ground

ed)

 

This wire is built-in user-programmable timer output provides a ground through this wire. Press the 

transmitter 

 and 

 

button at the same time. You may program the built-in timer to send a ground 

signal for any time interval between 1 second and 2 minutes. For instance, this timer output may be 
used to turn on the headlight with the remote control. Also on certain BMW, Mercedes Benz, Jaguar 
and Volkswagen cars, you can use this unique timed output to allow remote closure of all power window 
and sunroof without the need for an external module!   

H8/6 Black / Green wire – (-) 200mA Timer Control Channel 4 / Key Sensor Output – 
   Channel 4 Output 

(

See Alarm Feature

 

III – 5

 

Programming) 

(

Factory default setting

 on 

momentary ground

ed)

 

This wire is built-in user-programmable timer output provides a ground through this wire. Press the 

transmitter 

 and 

 

button at the same time. You may program the built-in timer to send a ground 

signal for any time interval between 1 second and 2 minutes. For instance, this timer output may be 
used to turn on the headlight with the remote control. Also on certain BMW, Mercedes Benz, Jaguar 
and Volkswagen cars, you can use this unique timed output to allow remote closure of all power window 
and sunroof without the need for an external module!   

Key Sensor By-Pass Output –

 

This output is for a Key sense wire by-pass that some Chrysler and Toyota vehicles need to activated 
remote start. It wire come on when the start is activated and stay on for 20 seconds. 

H8/7 Gray wire – (-) 200ma Channel 3 Output – 

This will become a 1 second pulse ground by activate channel 3 on transmitter for two seconds, the 
current capacity of this wire is 200 mA. This feature allows you to remote control trunk release or other 
electric device.   

H8/8 Pink wire – (-) 200ma

 Programmable Output (See Alarm Feature

 III – 2

 Programming) 

 

    2 Steps Unlock Output – (Factory default setting) 

The 2 steps unlock feature will work for the most fully electronic door lock circuit. The vehicle must have 
an electronic door lock switch (not the lock knob or key switch), which locks and unlocks all of vehicle's 
doors. When wired for this feature, press the disarm (or unlock) button one time will disarm the alarm 
and unlock the driver's door only. If, press disarm (or unlock) button two times within 3 seconds, the 
alarm will disarm and all doors will unlock. 

    Factory Security Disarm Signal Output – 

This wire is designed to disarm a factory installed security system. This wire sends a negative (-) 1 
seconds pulse upon a remote start and remote door unlocking. Some factory systems must be disarmed 
to allow remote starting. In most cases, this wire may be connected directly to the factory alarm disarm 
wire. The correct wire will show nagative ground when the key is used to unlock the doors or trunk. This 
wire is usually found in the kick panel area in the wiring harness coming into the car body from the door. 

Start Status (Shock Sensor By-Pass Control) Output–   

This wire is designed to by-pass shock sensor module. This wire will supply an output at all times the 
remote start is operating plus an additional 3 seconds after the remote start unit turn off. 

H8/9 Orange / White wire – 200mA Grounded Output when Disarmed – N.O. Disable – 

This wire will become grounded when the alarm is disarmed. The current capacity of this wire is 200mA. It 
can be connected to optional Ignition disable relay / ECU disable relay / Fuel Pump disable relay. 
 

 

87

87a

85

30

86

IN4003 Diode

H8/9

: Orange/White wire   

from control module

 

“Start” 

“On” 

X

Cut 

“Acc” 

“Off”

H1/4

 Yellow wire (Ignition 1 output)   

form Heavy Gauge wire harness

 

To Ignition Coil

 

H8/10 Orange wire – (-) 200ma Grounded Output When Armed – 

This wire will become grounded when the alarm is armed. The current capacity of this wire is 200mA. This 
output can control starter disable, when an intrusion is detected and the system is triggered. The vehicles 
prevent from any unauthorized starting.   

Содержание FM-870

Страница 1: ...FEB 20 2003 RST872 1 COMMANDO MODEL FM 870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL...

Страница 2: ...ue wire Ground Instant Trigger Input Zone 2 8 H5 5 White Green wire Diesel Wait To Start Input 8 H5 6 Green wire Negative Door Switch Sensing Input Zone 3 8 H5 7 Violet Wire Positive Door Switch Sensi...

Страница 3: ...ystem 13 PROGRAMMING TESTING A PROGRAMMING THE REMOTE TRANSMITTER 14 B FEATURES PROGRAMMING 14 Alarm Feature I Programming 14 3 30 seconds Delay Door Ajar Error Chirp 15 45 second Door By Pass With Do...

Страница 4: ...of vehicle Read operation manual for operating and programming routine Do not install any component near the brake gas pedal or steering linkage Some vehicles have a factory installed transponder immo...

Страница 5: ...rame 4 Brown Positive Output to Siren 5 Red 12V Input Two Way Transceiver Antenna LED Indicator 3A Fuse 10A Fuse 2 Red 12V Input 3 Red 12V Input 4 Yellow Ignition 1 output 1 Violet Starter Output 20A...

Страница 6: ...WHITE CONNECTOR FOR OUTPUT CONNECTION 4 White Wire 200mA Dome Light Control Output 7 Gray Wire 200mA Channel 3 Trunk Output 10 Orange Wire 500mA Grounded Output When Armed 1 Yellow Wire 200mA Ignitio...

Страница 7: ...connect this wire to the ignition switch side of the neutral safety switch can result in personal injury and property damage SEE NEUTRAL START SAFETY TEST FOR FURTHER DETAILS Start Cut Relay When Use...

Страница 8: ...pper left hand side of windshield Warning Do not mount in such a manner that it obstructs the driver s view Remove the protective tape backing Carefully align the two way transceiver antenna and apply...

Страница 9: ...ESTING YOUR INSTALLATION GUIDE IMPORTANT NOTE Directly connect the BLACK WHITE wire to the GROUND when this wire is not used H5 4 Blue wire Ground Instant Trigger Input Zone 2 This wire is the ground...

Страница 10: ...r wires with a test light or logic probe The vehicle will be damaged How to find a tachometer wire with your multi meter 1 Set the ACV or AC voltage 12V or 20V is fine 2 Attach the probe of the meter...

Страница 11: ...time interval between 1 second and 2 minutes For instance this timer output may be used to turn on the headlight with the remote control Also on certain BMW Mercedes Benz Jaguar and Volkswagen cars yo...

Страница 12: ...ase or other electric device H8 8 Pink wire 200ma Programmable Output See Alarm Feature III 2 Programming 2 Steps Unlock Output Factory default setting The 2 steps unlock feature will work for the mos...

Страница 13: ...does not have to be concealed however concealing the switch is always recommended as this provides an even higher level of security to the vehicle Mount the valet switch in a hidden but accessible loc...

Страница 14: ...voltmeter connecting to ground verify that you have th correct wire with the doors unlocked the voltmeter will receive 12 volts Lock the doors and the voltmeter wi read 0 volt Move the alligator clip...

Страница 15: ...s 1 LED flash 1 chirp 4 Depress the transmitter button A again to change the feature Simple keep re depressing the transmitter button A again until the module advances to your desired setting a In thi...

Страница 16: ...Push the Valet switch 4 times and hold it until two chirps with a long chirp is hearing then release the valet switch You are now in the Alarm feature II programming mode 3 Press and release the tran...

Страница 17: ...any interval between 1 second and 2 minutes 7 H8 2 Black Violet Wire Channel 6 Output Momentary output H8 2 Black Violet Wire Channel 6 Output Latched output H8 2 Black Violet Wire Channel 6 Output L...

Страница 18: ...n switch to ON position 4 Within 15 seconds enter your chosen second 9ths digit by pressing and releasing the valet Switch from 1 9 times 5 Finish by turning the ignition switch to OFF position If the...

Страница 19: ...this feature 6 Press button Activate Remote Start Press button Activate Remote Start Press button Activate Remote Start 7 H5 8 White Blue Wire 1 pulse activate H5 8 White Blue Wire 2 pulse activate H...

Страница 20: ...1 chirp to indicate your are in features RPM Learning mode 2 Start the vehicle with the key While the engine is running the parking LED will flash If don t please check tachometer White Red wire conne...

Страница 21: ...ecrease Start Timer is necessary c Repeat the step1 4 4 If the crank time is too short Engine not running while stops cranks a Press the button twice on the transmitter to stop engine running b Press...

Страница 22: ...first stage of the shock sensor Zone 1 system will emit a short chirp 2 Activate the full alarm second stage of the shock sensor Zone 4 system will emit a long chirp 3 Continue to test the shock senso...

Страница 23: ...the ignition switch to ON or RUN position But do not start the engine 4 Step on the brake pedal and shift the gear selector into DRIVE D 5 Put your foot over the brake pedal but do not press down on i...

Страница 24: ...either of the following key in sensor circuits if the operator inserts the ignition key while the vehicle is running under the control of the Remote Start the vehicle will shut down This must be expl...

Страница 25: ...e White Black H5 1 To Hood Pin Switch Safety Shut Down H5 1 1N4003 To connect to the key in sensor circuit as shown for method 2 A Locate the control wire that connects the drivers door pin switch to...

Отзывы: