manualshive.com logo in svg
background image

instruction manual

Camera Control Systems

AXP-CCS/AXM-CCS

Softwire Camera Centers

Содержание AXM-CCS

Страница 1: ...instruction manual Camera Control Systems AXP CCS AXM CCS Softwire Camera Centers ...

Страница 2: ... liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised ...

Страница 3: ...AXM CCS 4 Wiring the AXP CCS and AXM CCS 5 Preparing captive wires 5 Wiring guidelines 5 Using the AXP CCS mini XLR connector for AXlink data and power 5 Using the AXP CCS mini XLR connector for AXlink and an external power supply 6 Using the AXM CCS AXlink connector for data and power 6 Using the AXM CCS AXlink connector for data and an external power supply 6 Programming 7 Push Displays 7 Pushbu...

Страница 4: ...ii AXP CCS AXM CCS Softwire Camera Centers Table of Contents ...

Страница 5: ...with the open ended design architecture you can create a custom Axcess Control System program to accommodate your specific camera control application Specifications The following table lists the specifications for the AXP CCS and AXM CCS AXP CCS and AXM CCS Specifications Power Consumption 12 VDC 125 mA Dimensions HWD AXP CCS 4 00 x 10 00 x 8 00 including joysticks 10 16 cm x 25 40 cm x 20 32 cm A...

Страница 6: ...Product Information 2 AXP CCS AXM CCS Softwire Camera Centers ...

Страница 7: ...ckward until you can lay it down flat to expose the AXP AI8 and MSP circuit cards Locate the AXlink device DIP switch on the AXP AI8 circuit card FIG 1 and the MSP FIG 2 3 Set the AXlink device number on both the AXP AI8 and MSP by setting DIP switch positions 1 8 The total value of all ON up positions on the DIP switch sets the device number The AXlink DIP switch example shown in the following ta...

Страница 8: ...table top configuration and can be mounted on any flat surface FIG 4 shows the dimensions of the AXP CCS Mounting the AXM CCS The AXM CCS can be mounted in most types of electronic equipment racks FIG 5 the AXM CCS dimensions 1 Insert the AXM CCS into the equipment rack 2 Line up the top left and bottom right screw holes and start the 10 32 screws 3 Starting with the bottom left and top right scre...

Страница 9: ...e cable The following table lists wire sizes and the maximum lengths allowable between the camera centers and control system The maximum wiring length for using AXlink power is based on a minimum of 13 5 volts available at the control system s power supply This allows a total voltage drop of 1 5 VDC over the length of the wire If you install the camera centers farther away from the control system ...

Страница 10: ...ntrol system s AXlink connector to the AXlink connector on the rear panel of the AXM CCS as shown in FIG 9 Use an external 12 VDC power supply when the distance between the control system and AXM CCS exceeds the limits described in the Wiring Guidelines table on page 5 Make sure to connect only the GND wire on the AXlink connector when using an external 12 VDC power supply Do not connect the PWR w...

Страница 11: ... center PUSH device number button number The pushbutton response appears in the Axcess software program s PUSH window You can press the ALT and F keys on your keyboard to see what the pushbutton does in the software program You can also press the ALT and I keys to insert the pushbutton in the software program and enter the pushbutton s function FIG 10 AXP CCS pushbutton channel push codes FIG 11 A...

Страница 12: ... on the panel s pushbuttons DIM Dim mode 0 7 You may enter the configuration mode or toggle these functions as often required Levels Levels are the values that are related to the analog input or output on the AXP AI8 device in the AXP CCS The following table lists the levels LED Illumination Level Commands Mode Description 0 100 duty cycle default brightest setting 1 50 duty cycle 2 25 duty cycle ...

Страница 13: ...Programming 9 AXP CCS AXM CCS Softwire Camera Centers ...

Страница 14: ...ive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 048 004 1554 9 01 2001 AMX Corporation All rights reserved AMX the AMX logo the building icon the home icon and the light bulb icon are all trademarks of AMX Corporation AMX reserves the right to alter specifications without notice at any time In Canada doing business as Panja Inc ...

Отзывы: