Installation
5
AXP-CCS/AXM-CCS Softwire Camera Center
Wiring the AXP-CCS and AXM-CCS
The AXP-CCS and AXM-CCS communicate with the Axcess Control System via AXlink. The
AXP-CCS contains a mini-XLR connector on the rear panel for AXlink communication. The
AXM-CCS contains a 4-pin AXlink connector on the rear panel for AXlink communication.
Preparing captive wires
1.
Strip 0.25 inch of wire insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector according to the wiring
diagrams and connector types described in this section.
3.
Tighten the screws to secure the wire in the connector. Do not over-torque the screw; doing so
can bend the seating pin and damage the connector.
Wiring guidelines
The AXP-CCS and AXM-CCS require 12 VDC power to operate properly. The Axcess Control
System supplies power via the AXlink cable or external 12 VDC power supply. The maximum
wiring distance between the control system and camera centers determines power consumption,
supplied voltage, and the wire gauge used for the cable. The following table lists wire sizes and the
maximum lengths allowable between the camera centers and control system. The maximum wiring
length for using AXlink power is based on a minimum of 13.5 volts available at the control system's
power supply. This allows a total voltage drop of 1.5 VDC over the length of the wire.
If you install the camera centers farther away from the control system than recommended in the
Wiring Guidelines table, connect an external 12 VDC power supply to camera centers according to
the wiring diagrams described in this section.
Using the AXP-CCS mini-XLR connector for AXlink data and power
Connect the control system's AXlink connector to the mini-XLR connector (male) on the rear panel
of the AXP-CCS for data and 12 VDC power, as shown in FIG. 6.
Do not connect power to the Camera Center until wiring is complete. If you are using
a 12 VDC power supply, apply power to the panel only after installation is complete.
Wiring Guidelines
Wire Size
Maximum Wiring Length
18 AWG
938 feet
20 AWG
594 feet
22 AWG
368 feet
24 AWG
233 feet
FIG. 6
Mini-XLR connector to control system wiring diagram
1
2
3
4
4-pin mini-XLR connector
(external view)
4 - PWR +
3 - AXP
2 - AXM
1 - GND -
1
4
GND-
AXM
AXP
PWR+
2
3
Control system
Содержание AXM-CCS
Страница 1: ...instruction manual Camera Control Systems AXP CCS AXM CCS Softwire Camera Centers ...
Страница 4: ...ii AXP CCS AXM CCS Softwire Camera Centers Table of Contents ...
Страница 6: ...Product Information 2 AXP CCS AXM CCS Softwire Camera Centers ...
Страница 13: ...Programming 9 AXP CCS AXM CCS Softwire Camera Centers ...