7.  Install  right  brick  panel  using  the  same 

method described in step 5 for left brick 

panel.

8.  Replace 

deflec

tor  shield  using  screws 

removed in step 4.

9.  Follow instructions below to install logs, 

lava rock and ember material.

10. Close glass door, lock latches on top and 

bottom of door and replace screen (see 

steps 5 and 6 of 

Removing Glass Door

page 24).

11. Close top and bottom louvers.

Figure 44 - Installing Side Brick Panels

Left Side

Brick Panel

FIREPLACE INSTALLATION

Continued

INSTALLING LOGS, LAVA ROCK 

AND GLOWING EMBERS

Each  log  is  marked  with  a  number. These 

numbers will help you identify the log when 

installing. It is very important to install these 

logs exactly as instructed. Do not modify logs. 

Only use logs supplied with fireplace.

Open  louvers,  remove  screen,  unlock  door 

latches and open glass door. See steps 1 and 

2 of 

Removing Glass Door

, page 24. Install 

logs  according  to  instructions  for 

replace 

model numbers.
1.  Place log #1 (rear log) on top of grate. 

Make  sure  notches  in  bottom  of  log 

over grate (see Figure 45).

2.  Rest log #2 (large front log) on pins on 

front part of grate (see Figure 46). 

3.  Place log #3 (crossover log) onto rear and 

front logs. Make sure it is seated properly 

on smooth surface on front log and on pin 

on back log as shown in Figure 47.

4.  Place log #4 (right log) on pin on right side of 

front log as shown in Figure 48, page 26.

1

Figure 45 - Installing Log No. 1

2

Figure 46 - Installing Log No. 2

3

Figure 47 - Installing Log No. 3

5.  Place log #5 (base log) onto front left part of 

grate making sure notches 

fit

 over prongs 

of grate). See Figure 49, page 26.

Содержание CGDV32NR (PR)-3

Страница 1: ...ed service person to do this WARNING Ifthereisaduplex electrical outlet installed in the right side of the bottom of the fireplace base area be sure that theelectricalpowertotheoutletis turnedoffbeforeproceedingwith blower installation Failure to do this may result in serious injury Model BK Installation Follow all instructions provided in blower accessory kit 1 Attach power cord to blower motor by...

Страница 2: ...Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place green ground wire with r...

Страница 3: ...h Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Of...

Страница 4: ...re to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use...

Страница 5: ...gshow a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping syste...

Страница 6: ...ee Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Co...

Страница 7: ...see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit REMOVING REPLACING GLASS DOOR CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel ...

Страница 8: ...2 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING OPTIONAL BRICK LINER MODEL BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two hands Do not force b...

Страница 9: ... Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on front part of grate...

Страница 10: ...AD BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some ...