Figure 32 - Gas Connection
CSA
Design-Certified
Equipment Shutoff Valve with
1/8" NPT Tap*
3" Minimum
Approved
Flexible Gas
Line
Cap Pipe Nipple Tee Joint
Sediment
Trap/Drip Leg
Natural
- From
Gas Meter (5.5"
W.C. to 10.5"
W.C. Pressure)
Propane/LP
From External
Regulator (11"
W.C. to 14"
W.C. Pressure)
* The CSA
design-certified
equipment shutoff
valve may be
supplied
with the
appliance
or
you can purchase it from your retaile
r.
We
recommend
that you install a
sediment
trap/drip
leg in supply line as shown in Figure
32.
Locate
sediment
trap/drip
leg where it is
within
reach
for
cleaning.
Install in piping sys-
tem between fuel supply
and
fi
repla
c
e. Lo
c
ate
sediment
trap/drip
leg where
trapped
matter
is not likely to freeze. A
sediment
trap traps
moisture
and
contaminants.
This keeps them
from going into
fireplace
gas
controls.
If
sedi
-
ment trap/
dr
ip leg is not installe
d
or is installe
d
wrong, fireplace may not run properl
y.
FIREPLACE INSTALLATION
Continued
Figure 33 - Connecting Flexible Gas Line
to Millivolt Valve
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an open
fl
ame to check for a leak. Apply
noncorrosive leak detection
flui
d
to all joints. Bubbles forming show
a leak. Correct all leaks at once.
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Di
sc
onne
ct
fi
repla
c
e
and
its
individual
equip-
ment shutoff valve from gas supply piping
system. Pressures in e
xc
ess of 1/2 psig (3.5
kPa) will
damage
fireplace
gas regulator.
2. Cap off open
end
of gas pipe where equip-
ment shutof
f valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas
fi
repla
c
e or opening main gas
valve
loca
t
ed
on or near gas meter for natural
gas
fireplace
or using
compressed
air.
4.
Check
all joints of gas supply piping sys-
tem. Apply
noncorrosive
leak
detectio
n
fluid
to all joints. Bubbles forming show a
leak. Correct all leaks at once.
5. Re
c
onne
ct
firepla
c
e
and
equipment
shutoff valve to gas supply.
Check
recon
-
nected fittings for leaks.
Flexible Gas Line
Do NOT Kink
Equipment
Shutoff
Valve
To Gas Supply
(Natural)
To External
Regulator
(Propane/LP)
Control Valve
CONNECTING FIREPLACE TO GAS
SUPPLY
Installation Items Needed
•
5/16" hex socket wrench or nut-driver
•
sealant (resistant to propane/LP gas, not
provided)
1. Open lower louver
door
panel by gently
pulling forward.
2. Route
fl
exible gas line (prov
ided
by in-
staller) from equipment shutoff valve to
fireplace.
Route
flexible
gas supply line
through one of the
access
holes on
side
of fireplace.
3. Atta
ch
fl
exible gas line from gas supply to
control valve (see Figure 33).
4.
Check
all gas
connections
for leaks. See
Checking Gas Connections
.