4.   Be  certain  that  all  wire  terminals  are 

securely attached to terminals on blower 

motor  and  that  screw  retaining  green 

ground wire is tight. 

5.   Mount speed control box to switch bracket 

by  placing  plastic  control  shaft  forward 

through  opening  in  switch  bracket  (see 

Figure 27).

6.   While  supporting  speed  control,  secure 

control  shaft  with  lock  nut  by  pushing 

and turning lock nut with pliers clockwise 

until it is tight against front panel. Place 

provided control knob on shaft.

7.   Turn on power to duplex outlet if previ-

ously turned off per warning in column 2, 

page 17.

8.   Plug in blower power cord.

a.  If your 

firebox

 is installed as a free-

standing unit with an accessory man-

tel, determine whether power cord will 

exit  left  side  or  right  side  of 

firebox. 

Route  power  cord  through  exit  hole 

and plug power cord into a wall recep-

tacle near firebox.

b.  If your 

firebox

 installation is recessed 

and/or prewired, plug power cord into 

duplex outlet provided. Refer to your 

rebox owner’s manual for instructions 

on wiring duplex outlet.

 CAUTION: Never touch blow-

er wheel while in operation.

FIREPLACE INSTALLATION

Continued

Figure 27 - Attaching Speed Control to 

Firebox

Figure 28 - Location of Wiring Diagram 

Decal (Model May Vary From Illustration) 

Wiring Diagram 

Decal 12" in Front 

of Blower 

Speed 

Control 

Control 

Shaft 

Locknut 

Control 

Knob 

Switch 

Bracket

Blower 

Plug-In

Duplex Outlet

(Located underneath 

firebox floor against 

lower right outside wall)

Model BKT Installation

Note:  When  installing  BKT  thermostati-

cally controlled blower, you must 

first

 secure 

thermal switch bracket to blower if it has not 

already been factory installed.

1.  Place  green  ground  wire  with  ring  ter-

minal between bottom hole on thermal 

switch bracket and top ear hole on blower 

assembly.  Insert  Phillips  screw  into  all 

three  pieces  and tighten securely  (see 

Figure 29, page 19).

2.  Connect wire harness and power cord ter-

minals. Connect blue jumper wire to blower 

motor terminal and right side terminal of 

thermal switch. Connect black wire to left 

side of thermal switch and white wire to 

other remaining blower motor terminal.

Note:

 The power cord outer insulation sleeve 

may  have  to  be  stripped  slightly  to  allow 

enough  wire  length  to  reach  and  make  all 

connections. DO NOT trim excessive length 

away. Enable just enough to make all con-

nections securely.

9.  Check to make sure that power cord is 

completely  clear  of  blower  wheel  and 

that there are no other foreign objects in 

blower wheel. Turn blower on and check 

for operation. Turn blower off by turning 

knob fully counterclockwise before con-

tinuing.

10.  Peel off backing paper and stick supplied 

wiring  diagram  decal  on 

firebox

  bottom 

approximately 12" in front of blower (see 

Figure 28). 

Содержание CGDV32NR (PR)-3

Страница 1: ...ed service person to do this WARNING Ifthereisaduplex electrical outlet installed in the right side of the bottom of the fireplace base area be sure that theelectricalpowertotheoutletis turnedoffbeforeproceedingwith blower installation Failure to do this may result in serious injury Model BK Installation Follow all instructions provided in blower accessory kit 1 Attach power cord to blower motor by...

Страница 2: ...Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place green ground wire with r...

Страница 3: ...h Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Of...

Страница 4: ...re to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use...

Страница 5: ...gshow a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping syste...

Страница 6: ...ee Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Co...

Страница 7: ...see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit REMOVING REPLACING GLASS DOOR CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel ...

Страница 8: ...2 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING OPTIONAL BRICK LINER MODEL BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two hands Do not force b...

Страница 9: ... Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on front part of grate...

Страница 10: ...AD BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some ...

Отзывы: