FIREPLACE

INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS

HAND-HELD REMOTE CONTROL 

HRC100 AND HRC200 SERIES

NOTICE: Use only alkaline bat-

teries (not included).

Installing Remote Receiver

1.  Open  bottom  louver  and  locate  switch 

bracket on the left.

2.  Unscrew  switch  bracket.  Lean  bracket 

forward  so  you  are  able  to  access  the 

back of remote receiver.

3.  Locate  battery  clip  mounted  on  back  of 

receiver. Slide a 9-volt alkaline battery (not 

included) through the clip (see Figure 38).

4.  Attach terminal wires to battery.
5.  Connect wires from receiver to TH and 

TPTH to control valve (see Figure 39).

6.  Replace switch bracket.

Figure 38 - Attaching Alkaline Battery to 

Receiver

Figure 39 - Control Valve Terminals

To Optional 

Remote 

Accessory

9-Volt 

Alkaline 

Battery 

Receiver 

Terminal 

Wires 

Battery Clip 

o

Th rm

Installing 9-Volt Alkaline Battery in Hand-

Held Remote Control Unit 

1.  Remove battery cover on back of remote 

control unit (see Figure 40).

2.  Attach  terminal  wires  to  battery.  Place 

battery into battery housing.

3.   Replace battery cover onto remote control 

unit. 

Figure 40 - Installing Battery in Hand-

Held Remote Control Unit

9-Volt 

Battery

Battery 

Housing

Battery Cover

Terminal 

Wires

Remote Control Unit

REMOVING/REPLACING GLASS

DOOR

  CAUTION:  Do  not  operate 

this 

replace with a broken glass 

door panel or without the glass 

door panel securely in place. For 

replacement part information see 

Replacement Parts

, page 36.

 CAUTION: Wear gloves and 

safety glasses while handling or 

removing broken glass. Do not re-

move if glass is hot. Keep children 

and pets away from glass.

  WARNING:  If 

fireplace

  has 

been running, turn off and un-

plug 

fir

eplace. Let cool before re-

moving glass door or louvers.

Removing Louver Panels

Remove  top  and  bottom  louver  panels  by 

simultaneously  pulling  both  top  end  spring 

latches  towards  center  of  appliance  until 

they  are  disengaged  from  locating  holes 

(see  Figure  41).  Repeat  for  bottom  spring 

latches  and  pull  louvers  outward. To  install 

or  replace  items  removed,  simply  reverse 

procedures above.

Figure 41 - Removing Louver Panel

Louver Panel

Spring Latch

Содержание CGDV32NR (PR)-3

Страница 1: ...ed service person to do this WARNING Ifthereisaduplex electrical outlet installed in the right side of the bottom of the fireplace base area be sure that theelectricalpowertotheoutletis turnedoffbeforeproceedingwith blower installation Failure to do this may result in serious injury Model BK Installation Follow all instructions provided in blower accessory kit 1 Attach power cord to blower motor by...

Страница 2: ...Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place green ground wire with r...

Страница 3: ...h Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Of...

Страница 4: ...re to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use...

Страница 5: ...gshow a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping syste...

Страница 6: ...ee Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Co...

Страница 7: ...see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit REMOVING REPLACING GLASS DOOR CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel ...

Страница 8: ...2 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING OPTIONAL BRICK LINER MODEL BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two hands Do not force b...

Страница 9: ... Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on front part of grate...

Страница 10: ...AD BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some ...

Отзывы: