Comfortflame CGDV32NR (PR)-3 Скачать руководство пользователя страница 6

Test Pressures Equal To or Less Than 

1/2 PSIG (3.5 kPa)

1.  Close equipment shutoff valve (see Fig-

ure 34).

2.  Pressurize supply piping system by either 

opening propane/LP supply tank valve for 

propane/LP gas 

replace or opening main gas 

valve located on or near gas meter for natural 

gas 

fireplace

 or using compressed air.

3.  Check all joints from propane/LP supply 

tank  for  propane/LP  or  gas  meter  for 

natural  gas  to  equipment  shutoff  valve 

(see Figure 35 or Figure 36). Apply non-

corrosive leak detection 

fluid

 to all joints. 

Bubbles forming show a leak. Correct all 

leaks at once.

Open

Closed

Equipment 

Shutoff Valve

Figure 34 - Equipment Shutoff Valve

PRESSURE TESTING FIREPLACE GAS

CONNECTIONS

1.  Open equipment shutoff valve (see Fig-

ure 34).

2.  Open main gas valve located on or near 

gas meter for natural gas or open supply 

tank valve for propane/LP gas.

3.  Make sure control knob of 

fireplace

 is in 

the OFF position.

4.  Check  all  joints  from  equipment  shutoff 

valve to gas valve (see Figure 35 or Figure 

36). Apply  noncorrosive  leak  detection 

fluid

 to all joints. Bubbles forming show a 

leak. Correct all leaks at once.

5.  Light 

fireplace

 (see 

Operation

, page 26). 

Check all other internal joints for leaks.

6.  Turn off 

fireplace

 (see 

To Turn Off Gas to 

Appliance

, page 27).

INSTALLING OPTIONAL WALL

MOUNT SWITCH - GWMS2

1.  Connect  one  terminal  of  25  ft.  wire  for 

wall  switch  to TPTH  terminal  on  valve. 

Connect  remaining  wire  terminal  to TH 

terminal on valve. Make sure that wire ter-

minals are in positions on unit as pictured 

in Figure 37. If wires are not connected as 

shown the switch will not work.

2.  Route 25 ft. wire through openings pro-

vided on sides of burner system to a con-

venient location to mount your switch.

3.  Connect one bare wire end to each of the 

terminals of the GWMS2 wall switch.

4.  Install wall switch and cover in wall.

Figure 35 - Checking Gas Joints for 

Propane/LP Gas Fireplace

Propane/LP 

Supply Tank

Gas Va ve

Equipment Shutoff Valve

Figure 36 - Checking Gas Joints for 

Natural Gas Fireplace

Gas 

Meter

Gas Valve

Equipment Shutoff Valve

Figure 37 - Connecting Wall Switch to 

Control Valve

To Wall 

Switch 

Accessory

FIREPLACE INSTALLATION

Continued

Содержание CGDV32NR (PR)-3

Страница 1: ...ed service person to do this WARNING Ifthereisaduplex electrical outlet installed in the right side of the bottom of the fireplace base area be sure that theelectricalpowertotheoutletis turnedoffbeforeproceedingwith blower installation Failure to do this may result in serious injury Model BK Installation Follow all instructions provided in blower accessory kit 1 Attach power cord to blower motor by...

Страница 2: ...Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place green ground wire with r...

Страница 3: ...h Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Of...

Страница 4: ...re to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use...

Страница 5: ...gshow a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping syste...

Страница 6: ...ee Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH terminal on valve Co...

Страница 7: ...see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit REMOVING REPLACING GLASS DOOR CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel ...

Страница 8: ...2 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch INSTALLING OPTIONAL BRICK LINER MODEL BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two hands Do not force b...

Страница 9: ... Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on front part of grate...

Страница 10: ...AD BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some ...

Отзывы: