Currency
Set the currency used when metering consumption on the supervisor.
Group
Different energy meter modules can be included in one group to create a single display. For example, in the case of a three-phase
system there may be 3 load and consumption control modules; these may be included in the same group in order to create a single
chart showing the total of the 3 consumption values on the supervisor. To add a group press the "+" button at the top of the column
and enter the name of the group you wish to create. In the group
fi
eld, select the name of the group created previously or select
"Single device" if the value recorded is not part of a group and should generate its own chart.
Scale factor
For inputs connected to pulse meter modules, a divider can be set to customise the display according to the values recorded by the
meter with pulse output used. For example, if you are using a water meter which counts the litres and generates a pulse for every litre,
and if you want the supervisor to display the cubic metres (1000 litres), you need to set the display divider to 1000.
CO2 constant
In the case of electricity production systems, it is possible to set the CO2 constant saved by the system producing the energy. If there
are several inputs set as production (for example, in a three-phase photovoltaic system), they must all be set with the same value.
The value can subsequently by modi
fi
ed through the supervisor menu. The CO2 graphic is automatically displayed by the supervisor
when a chart representing energy production is present.
View single
This
fi
eld must be selected, when the input has been assigned to a group, if as well as the chart relating to the selected group you
also want to view a chart for the individual input. For example, if you are using 2 load and consumption modules, 1 to display electrical
socket consumption and 1 to display lighting consumption, you can create a group which includes both and which generates a chart
by adding the consumption values for the two modules together. If the "View single"
fi
eld is selected for both, the two individual charts
for the two load and consumption modules will be shown in addition to the general chart.
Comparison
Different charts set as both production and consumption can be assigned to a single chart to make a comparison between the energy
produced and consumed by the system. If in the "Comparison"
fi
eld you select 3 modules recording consumption and one module
recording the energy produced, a chart with the title "Comparison" is generated on the supervisor; this superimposes all the energy
consumed by the selected modules over the energy produced by the selected production module. This display offers at-a-glance
understanding of whether more energy has been consumed than has been produced or vice-versa in the different options displaying
data on a daily, monthly or annual basis, or even using the information logged in the last 5 months.
Activation
This column determines the situation in which the conditioned scenario will be activated depending on the input status (see paragraph
3.5.10).
Rooms
This column determines to which room in the home the module output will be assigned.
Name Associated Scenario
This column determines the name of the conditioned scenario which will appear on the Planux Manager / Minitouch monitor (see
paragraph 3.5.10).
Unit of measurement
Enter, for inputs connected to pulse meter modules only, the unit of measurement for the value recorded and used in supervisor
charts and tables. For example, "l" for litres if a water meter is
fi
tted, m3" for cubic metres of methane if a methane meter is
fi
tted. It is
not necessary to set a unit of measurement for electricity meters as the reading is taken in Watts.
90
Содержание simplehome
Страница 1: ...www comelitgroup com EN TECHNICAL MANUAL Technical manual for the SimpleHome system...
Страница 35: ...Fastening Unfastening Sensor mounting 35...
Страница 41: ...150 cm 120 cm Minitouch timer thermostat mounting 41...
Страница 43: ...Planux Manager mounting 14 5 cm 14 5 cm 140 145 cm 115 125 cm 2 3 4 5 1 ALTO UP HAUT OBEN 1 2 2 3 43...
Страница 45: ...Minitouch mounting 150 cm 120 cm 45...
Страница 76: ...Load management module 76...
Страница 78: ...78...
Страница 107: ...107...
Страница 108: ...7 edizione 03 2014 cod 2G40001063...