normal button connected to a digital input on a module.
If "Dimmer" mode is set, you will also need to set the "Start dimmer" value. The "Start dimmer" value can be set between 0 and 255,
and corresponds to the 0-10 V output value converted to 8-bit format. It enables the setting of a minimum value for the 0-10 V output;
the output will never be adjusted under this value.
This option can be used to "cut" downward adjustment and achieve more continuous adjustment of the output, and therefore the lamp,
without "dead" time with the lamp switched off.
ZONE:
set the number of the zone to which you want to associate the analogue output. All the outputs associated to the same zone will
be controlled by the same command. This option is useful if you want to switch off all the lights using a single button. In this case all the
lights which should be controlled simultaneously by one button will be set with the same zone number. The same procedure can be
set via a scenario programmed on a supervisor (for example, Planux Manager or Minitouch) which is activated when a button, which
should be set as "Supervisor", is pressed.
73
Содержание simplehome
Страница 1: ...www comelitgroup com EN TECHNICAL MANUAL Technical manual for the SimpleHome system...
Страница 35: ...Fastening Unfastening Sensor mounting 35...
Страница 41: ...150 cm 120 cm Minitouch timer thermostat mounting 41...
Страница 43: ...Planux Manager mounting 14 5 cm 14 5 cm 140 145 cm 115 125 cm 2 3 4 5 1 ALTO UP HAUT OBEN 1 2 2 3 43...
Страница 45: ...Minitouch mounting 150 cm 120 cm 45...
Страница 76: ...Load management module 76...
Страница 78: ...78...
Страница 107: ...107...
Страница 108: ...7 edizione 03 2014 cod 2G40001063...