CONNECTION TERMINALS
Term.
Function
-
BUS power supply negative
+
BUS power 24 Vdc
D
BUS data line
IA2
Input 2 (0-10 V)
V-
GND
+10
+10 Vdc support at input 2
IA1
Input 1 (0-10 V)
V-
GND
+10
+10 Vdc support at input 1
OA1
Output 1 (0-10 V)
V-
Output 1 support negative
OA2
Output 2 (0-10 V)
V-
Output 2 support negative
N.B. The module must be programmed via the BUS line, using the SimpleHome/RS232 interface (20022611) and the SimpleProg
programming software.
Speci
fi
cations are subject to change without notice.
green (bus)
red (+)
blue (-)
DIMMER OR BALLAST