Tech Support: 1‐818‐841‐5500
9
For easier maintenance there are two
counters on the front panel.
The
CYC
counts the number of blast cycles on
the AccuFlo (each time the PowderGate®
valve opens.)
Abrasive type and blast pressure will impact
maintenance frequency, but typical
configurations will last more than 250,000
cycles before needing maintenance.
The
HRS
counter records the number of blast
hours (i.e. actual time the modulator has
operated.)
To replace the AccuFlo® AF10‐CE
modulator:
•
Disconnect 3 colored tubes from the
modulator and the electrical plug
from front panel.
•
Remove the two screws holding the
modulator to the bracket using a
Phillips screwdriver.
•
Install new the modulator in reverse
order, making sure the two grommets
remain in the bracket.
AccuFlo
®
AF10‐CE Modulator
MODULATOR
MB2250‐1 (115V)
MB2250‐2 (220V)
Maintenance Counters
Your maintenance requirements may vary with your application.
The modulator should be replaced after 2000 hours of operation.