instruction for the service people
17
LOCATION
The machine has to be installed in a “normal” room or environment, which is adequately
ventilated, dust free, well illuminated and without risk of explosion.
INSTALLATION AND CONNECTIONS
The installation of the dishwasher requires previously prepared supplies for the electrical and
hydraulic connections, as indicated on the enclosed installation plan and data plates which refer
to the model of your choice.
In order to prevent damage due to the emission of steam from the machine, ensure that
adequate ventilation/extraction is available.
Remove lower panels and position the machine over service connections. Fit the standard
rubber absorbers supplied under the adjustable feet of the machine and adjust them to level it,
if necessary.
Connect the load and unload tables. It is advisable to fit a table crowding switch "SS1" on the
unload table. For the electrical connection, see fig.4.
The supplier of detergents has to provide the required dispensers.
Attention: The supply of detergents and hygienic products should be provided by the use of
automatic dispensers, as it is not possible to obtain adequate quantities, when pouring the
detergent directly into the tank. There is also the risk that brown spots may appear on the
surfaces due to the reaction of chloride.
The introduction of the detergents must take place near the suction tube of the pump, the
minimum distance from the bottom must be 15 cm in order to avoid corrosion.
ELECTRICAL CONNECTION
The electrical supply voltage must correspond with the machines electrical requirements, as
indicated on the machines data plate
Electric supply has to be isolated via a wall mounted three-pole circuit breaker having a contact
separation in all poles that provide full disconnection under overvoltage category III conditions
in accordance with the wiring rules. For the dimensions of above refer to the “Technical data
sheet” on page 1 of this instruction manual (Recommended residual current circuit breaker
Type A, 400V, Id=0,03A).
The section of the supply cables must not be inferior to that indicated in the “Technical data
sheet”. If the cable is not protected use a flexible cable with protective covering in
polychloropene with characteristics matching at least type H07RN-F.
The cable must be connected to the terminal “PE” of the grounding bar.
The electrical safety of this machine is guaranteed only on condition that it is connected as
follows.
Содержание COMENDA AC2E
Страница 1: ...INSTRUCTION MANUAL FOR DISHWASHING Mod AC2E AC2E P5 AC2E P6 AC2E P9 ...
Страница 2: ...CORNER VERSION DHM ...
Страница 4: ...instruction for the user 4 ...
Страница 6: ...instruction for the user 6 ...
Страница 9: ...instruction for the user 9 INSTRUCTIONS FOR USE ...
Страница 28: ...AC2E tech eng 04 2015 ...