INSTALLATION GUIDE FOR RA-5200
RA-5200 QI
Copyright - refer to title page
Page 64
ENU Status : 1-0-0
4.3.4.3 ALARM INFORMATION
Alarm information is equipment specific.
The alarm parameters include Master Alarm and Channel
Alarm. All alarm information, in general, will be displayed in the right part of the main screen when
clicking on each node of the [Alarm Info.]. Please refer to Reference 0.6.3 OMT v3.20 Software
Product Manual for the specified operation details. Following is the alarm list of RA-5200-D, RA-5200-
O and RA-5200-R.
Alarm name
RA-5200-D
RA-5200-O
RA-5200-R
GSM/DCS/WCDMA Uplink LNA Fault
GSM/DCS/WCDMA DL PA Alarm
GSM/DCS/WCDMA Downlink Input Overload Alarm
Chassis Lock Alarm
MCU Battery Fault Alarm
Optical Receiver Alarm
Optical Transmitter Alarm
Equipment Over Temperature Alarm
Power Supply Down Alarm
Power Supply Fault Alarm
Master-Slave Monitor Link Alarm
External Alarm 1~4
Table 26: Alarm List for RA-5200
Refer to Reference 0.6.3 OMT v3.20 Software Product Manual for the alarm configuration and alarm
levels.
4.3.4.4 PROPERTIES INFORMATION
Properties information is equipment specific. The property parameters include Equipment ID, Chip
Info., Equipment Info., Site Location, Comm. Config. that are equipment specified. All properties
information, in general, will be displayed in the right part of the main screen when clicking on each
node of the [Properties Info.].
There are three separate interfaces for [Properties Info.] group.
Node Name
Description
[Equipment ID]
Displays the site ID and site sub ID of the system
[Firmware Info]
Displays the firmware information of the chip
[Equipment Info]
Displays the equipment information as Equipment Type, Equipment Model
and Equipment Manufacture Serial Number
[Site Location]
Displays the longitude and latitude of the equipment installation site. This
information can be viewed directly when equipment signals are connected
[Comm. Config]
Displays the equipment information in groups of IP address, Phones Code,
Report Config, SMSC Number, etc. The relevant information in these groups
can be inserted by users when equipment signals are connected. MOU
specific
Refer to Reference 0.6.3 OMT v3.20 Software Product Manual for the specific description on
Properties Information.