![Comba Telecom RA-5200 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/comba-telecom/ra-5200/ra-5200_installation-manual_2639105050.webp)
INSTALLATION GUIDE FOR RA-5200
RA-5200 QI
Copyright - refer to title page
Page 49
ENU Status : 1-0-0
3.4.3 RRU CONNECTORS
Connectors on the RRU are identified below:
DT
WCDMA
DT
GSM900
DT
GSM1800
RS-485
MT
200-240V 50Hz/60Hz
Fig 25: RRU connectors
RS-485
5-PIN round connector, is the communication port for connection to ROU
with the supplied communication cable
EXT_ALM
7-PIN round connector for connection to the external facilities
MT
N-F connector for connection to service antenna
DT GSM900
RF connector, is connected to the “DT GSM900” port of ROU for GSM900
signals transmission. A load will be applied when unused.
DT WCDMA
RF connector, is connected to the “DT WCDMA” port of ROU for WCDMA
signals transmission. A load will be applied when unused.
DT GSM 1800
RF connector, is connected to the “DT GSM1800” port of ROU for
GSM1800 signals transmission. A load will be applied when unused.
200~240V
50Hz/60Hz
A pre-installed power cord provided for connection to AC 220V power
supply
Table 20: RRU connections