RATINGS, DATA, AND DIMENSIONS
NATURAL GAS STEAM BOILERS
Boiler
Number
&
Damper
Input
Btu/Hr.
Heating
Capacity
Btu/Hr.
Net
Steam Rating
Gas
Inlet
Size
Dimensions
Water Content
(Gallon
Capacity)
Annual Fuel
Utilization
Ef
fi
ciency
(AFUE)
Btu/Hr.
Sq.
Ft.
A
B
C
D
E
F
G
To
Water
Line
To
LWCO
Line
Elec.
Ign.
Std.
Pilot
CEG112C 112,500
90,000
67,500
281
½
14¼
27
⅝
24
⅛
5
3½
6
44¾
4.8
3.0
81.0
78
CEG150C 150,000
120,000
90,000
375
½
17
⅛
28
⅝
24
⅝
6
4
6½
45¼
6.0
3.7
81.0
78
CEG187C 187,000
151,000
113,300
472
½
20
29
⅝
25
⅛
7
4½
7
45¾
7.0
4.4
81.0
78
CEG225C 225,000
181,000
135,800
556
¾
22
13
/
16
30
⅝
25
⅝
8
5
8
46¾
8.4
5.0
81.0
78
CEG262C 262,500
212,000
159,000
663
¾
25
⅝
30
⅝
25
⅝
8
5
8
46¾
9.5
5.8
81.0
78
CEG300C 299,999
243,000
182,300
760
¾
28
⅛
31
⅝
26
⅛
9
5½
10
48¾
10.7
6.4
81.0
78
NOTE:
For altitudes above 2,000 ft. ratings should be reduced at the rate of 4% for each 1,000 ft. above sea level,
The MEA number for the CEG series is 17-79.
Electrical service to be 120 Volts, 15 Amps, 60 Hz.
**For equivalent square feet of radiation, divide output by 240.
STANDARD EQUIPMENT:
Crafted Boiler, Drafthood, Low Water Cut-off (Probe Type), Deluxe Jacket, Wiring, Automatic
Vent Damper, Ported Stainless Steel Burners, Blocked Vent and Roll-Out Safety Switches, Gas Valve, Pilot, Pressure
High Limit Control, 2-2" Supply Tapping-L.H. Plugged, 2-2" Return Tappings-L.H. Plugged. Packed in Separate Carton:
Pop Safety Valve and Boiler Drain.
OPTIONAL EQUIPMENT:
Electronic water feeder
The Ratings marked “Net” indicate the amount of equivalent direct cast iron radiation each boiler will take care of under
normal conditions and thermostatic control. The Net Steam Ratings shown are based on a piping and pickup allowance
of 1.333. Proper allowance has been made for piping and pickup in accordance with the factors shown in the Standard
as published by The Hydronics Institute.
Selection of boiler size should be based upon Net BTU per Hour of the connected radiation and piping.
The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup
requirements.
In line with it's policy of product improvement, Utica Boilers reserves the right to make changes without notice.
LEFT SIDE VIEW
FRONT VIEW
RIGHT SIDE VIEW
Содержание CEG-C
Страница 30: ...30 INSTALLATION NOTES ...
Страница 31: ...31 INSTALLATION NOTES ...
Страница 32: ...COLUMBIA COMPANY Main offices and factory Pottstown PA ...