LIGHTING INSTRUCTIONS
!
WARNING
If you do not follow these instructions
exactly, a
fi
re or explosion may result
causing personal injury or loss of life.
Before any procedures are attempted on this
appliance, it is necessary to determine if the ignition
system is intermittent or continuous pilot system. If
you are uncertain, contact the manufacturer before
proceeding.
!
CAUTION
Before operating, make certain steam
boiler is full of water to water line
and system is vented of air. See the
operating lighting instructions.
LIGHTING PROCEDURE FOR BOILER WITH
INTERMITTENT PILOT SYSTEM.
FOR YOUR SAFETY READ BEFORE OPERATING.
• This appliance is equipped with an ignition system
which automatically lights the pilot. Do not try to
light the pilot by hand.
• Before operating smell all around the appliance
area for gas. Be sure to smell next to the
fl
oor
because some gas is heavier than air and will
settle on the
fl
oor.
!
CAUTION
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the
fi
re department.
• Use only your hand to push in or turn gas control
knob. Never use tools. If the knob will not push
in or turn by hand, don’t try to repair it, call a
quali
fi
ed service technician. Force or attempted
repair may result in a
fi
re or explosion.
• Do not use this appliance if any part has been
under water. Immediately call a quali
fi
ed service
technician to inspect the appliance and to replace
any part of the control system and gas control
which has been under water.
OPERATING INSTRUCTIONS FOR
INTERMITTENT PILOT SYSTEMS
1.
STOP!
Read all safety information starting on
this page.
2.
Set thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
This appliance is equipped with an ignition device
which automatically lights the pilot. DO NOT try
to light the pilot by hand.
5.
Remove access panel (if present)
6.
Push in gas control knob slightly and turn
clockwise
to “OFF.”
7.
Wait
fi
ve (5) minutes to clear out any gas. If you
then smell gas, STOP, Follow “B” in the safety
information “What To Do If You Smell Gas”. If you
don’t smell gas, go to the next step.
8.
Turn gas control knob counterclockwise
to “ON.”
9.
Replace control access panel (IF PRESENT).
10.
Turn on all electric power to the appliance.
11.
Set thermostat to desired setting.
12.
If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and
call a quali
fi
ed service technician or your gas
supplier.
13.
Do not use this appliance if any part has been
under water. Immediately call a quali
fi
ed service
technician to inspect the appliance and to replace
any part of the control system and any gas
control which has been under water.