Figure 8 - Intermittent Pilot Gas Valve
LIGHTING INSTRUCTIONS
Figure 9 - Continuous Pilot Gas Valve
LIGHTING INSTRUCTIONS FOR BOILER
WITH CONTINUOUS PILOT SYSTEM.
1.
Stop
! Read the safety information starting on
page 17.
2.
Set thermostat to lowest setting.
3.
Turn off all electric power to the appliance.
4.
Remove manifold cover and burner door, (
fi
gures
10 & 12).
LIGHTING PROCEDURE FOR BOILER WITH
CONTINUOUS PILOT SYSTEM.
FOR YOUR SAFETY READ BEFORE OPERATING.
• Read Warning on page 16.
• This appliance is equipped with a pilot which must
be lighted by hand. When lighting the pilot follow
these instructions exactly.
• Before operating smell all around the appliance
area for gas. Be sure to smell next to the
fl
oor
because some gas is heavier than air and will
settle on the
fl
oor. Follow Caution on page 16
for safety information for what do do if you smell
gas.
• Use only your hand to push in or turn gas control
knob or reset button. Never use tools. If knob or
reset button will not push in or knob will not turn
by hand, don’t try to repair it. Call a quali
fi
ed
service technician. Force or attempted repair may
result in
fi
re or explosion. See
fi
gure 9.
• Do not use this appliance if any part has been
underwater. Immediately call a quali
fi
ed service
technician to inspect the appliance and to replace
any part of the control system and any gas
control which has been under water.
5.
Turn gas control knob clockwise
to “off” (See Note #1).
NOTE
: Some gas control knobs cannot be turned
from “pilot” to “off” unless knob is pushed in
slightly. Do not force.
6.
Wait (5) minutes to clear out any gas. If you
smell gas, stop! Follow safety information “What
to do if you smell gas,” located on page 16 of this
manual. If you don’t smell gas, go to the next
step.
7.
Find pilot. Follow metal tube from gas control.
Depending on the model of the boiler, pilot is
mounted on the base or on one of the burner
tubes.
8.
Turn gas control knob counterclockwise
to “pilot”.
9.
Push in gas control knob, or reset button if so
equipped, all the way in and hold. Immediately
Light the pilot with a match. Continue to hold the
gas control knob or reset button for about one
(1) minute after the pilot is lit. Release knob or
button and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 9.
• If knob or button does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob clockwise
to “off” (see note*) and call a service
technician or gas supplier.
10.
Replace burner door and manifold cover, (
fi
gures
10 & 12).
11.
Turn gas control knob counterclockwise
to “on”.