41
After refilling, the cylinders must not be emptied
completely, even during winter storage, to prevent
damp air from getting in (Fig. 58).
3
Check the condition of the hoses and the relative connectors.
See paragraph 6.2.2 “Connecting the refill hoses”.
AUTOMATIC CONDENSATE DISCHARGE
4
For the models provided with an automatic
condensate discharge, a special conden-
sate collection tank has been fitted in the
side compartment of the compressor
(Fig. 59-60).
The outlet of water vapourized with lubricating
oil should be considered normal during
refilling: the quantity is in direct relation to
the percentage of humidity present in the
air.
The condensate must be disposed of
according to the instructions given in
chapter 10.2 “Disposal of waste”.
58
59
MCH 13-16/ET Compact
MCH 26-32/ET Compact
60
Use