14
Click
[Load]
, choose the correct parameter file.
Click
[Send]
, to send the loading parameters to the receiving cards. At the moment, each
cabinet should display normally (it is normal status even the picture between cabinets is not
continuous), then click
[Save To Receiver]
to save the parameters to the receiving cards.
If each cabinet cannot display normally, you can conduct via the
Basic Setting
(
Module
Information
,
Box Setting
,
Performance Setting
) or
Intelligent Setting
, and you can also contact
with the LED screen engineers.
5.2.3 Connection Parameters Setting
Users don’t need to set up the control area of each net port respectively, but to the
connection relationship between the receiving cards under the network port loading via each
sender, and the software will auto calculate and set up the port control area according to the
connection relationship.
Detailed setting steps as follows:
①
Set up the quantity of receiving card
Set how many receiver (receiving card) that one port manages in Row Count and Col Count
(12*12 as an example) according to the actual loading of LED display, you will see LED display
mapping area from the right side (Viewing from the front of LED display).