Page
15
of
46
Vulcan Prime
5. Chiller Operating Instructions
Note:
Please read all the operating instructions carefully before using and following it.
Important Instructions
•
Please confirm that the input voltage is AC 220V and make sure no coolant leakage from joints of water
pipes before starting the equipment.
•
Please confirm the cooling system is ON before turn on the UV LED lamp. Please shut down the main
power from the electrical board and then shut the cooling equipment after 3 minutes.
•
Please confirm that the ambient temperature of the equipment shall be maximum 35
0
C.
•
Please confirm that the dust proof net must be cleaned weekly.
•
Please confirm that the distance between UV LED lamp and printer nozzle is suggested to be more than
5cm.
•
Better to use antifreeze coolant.
Chiller Features
•
Mercury free, safer, more environmentally friendly and energy efficient.
•
Adopting more integrated COB package and available for customization.
•
The UV LED lamp can instantly start up and work without preheating and standby mode.
•
Unique design of small size and simple structure makes easier installation.
•
Recycling coolant and rapid heat dissipating COB ensures longer lifespan of the UV LED lamp source.
•
Higher luminous efficiency, less power consumption, long lifespan.
•
The UV LED lamp is suitable for many curing base materials, like the soft, rigid, absorbent and non-
absorbent materi
als. Don’t need to deal with the heat radiation of thermosensitive base material.
•
The UV LED light source is narrow band, which only give out useful light and no harmful UV light. As a cold
light source, the components have very low thermal radiation which cut much heat during curing process.
Operation Rules
•
Connect the AC 220V 50Hz power cable, signal control cable, UV LED lamp power cable and cooling
circulation water pipes. If the cooling equipment and power board are separate please connect them with
signal cable.
•
Add coolant to the required level. Anti-freezing coolant must be used in freezing region.
•
Switch on the power supply to confirm the operation of the water pump, the water pipe
s aren’t bent and
no coolant leakage. After 3-5 minutes operation, the air will be out from the pipes because the length and
reservoir volume of the water tank is enough. If not, please add the coolant again.
•
Connect the signal cable (make sure the input voltage is within 3-24V). When the signal pass, the UV LED
lamp is ON and when the signal stop the UV LED lamp is OFF.
•
Adjustment the potentiometer to control the power of the UV LED lamp.
Содержание Vulcan Prime
Страница 1: ......
Страница 5: ...Page 4 of 46 Vulcan Prime Machine Errors 44...
Страница 46: ......