background image

 

 Collomix GmbH 

 

VISCO

 

550 

 

 

Version 1.1-17

 

17 

8.3

 

 Repair 

If service is required, please consult the customer service or the manufacturer of the machine. 

DANGER 

Danger of death by dangerous voltage 

Do not open the housing or remove any safety equipment of the machine. Please note that all 

maintenance and servicing jobs must be left strictly to authorized and suitably trained expert staff. 

The proper state of all safety equipment and electrical equipment is to verify and document after 

the repair. 

 

 

 

Only use original spare parts.  

 

Do not modify or change safety-related parts! 

 

Any additional components added may not impair safety and must be approved by the 

manufacturer. 

8.4

 

Expendable items 

The following expendable items are available for the device: 

 

Part 

Article no.: 

Bag 10 pcs. of rubber for the handle safeguard 200 mm Ø 

61326 

Bag 10 pcs. of rubber for the handle safeguard 160 mm Ø 

61327 

Bag 10 pcs. of rubber for the handle safeguard 140 mm Ø 

61328 

Grease ESSO BEACON EP 

61299 

 

Spare parts are available under www.collomix.de. 

 

Содержание VISCO 550

Страница 1: ...Version 1 1 17 Instructions Biaxial Mixer VISCO 550 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Страница 2: ...VISCO 550 Collomix GmbH 2 Version 1 1 17...

Страница 3: ...ransport rollers 10 5 4 Mains connection 10 5 5 Trial run 10 6 Operation 11 6 1 Switching on the machine 11 6 2 Load a container 11 6 3 Starting the mixing cycle 12 6 4 Ending the mixing cycle 12 6 5...

Страница 4: ...1 17 1 Layout Drawings 1 1 Machine components Machine components 1 Machine legs 5 Manual door release 2 Sliding door 8 Control panel CSE 3 Main switch and DC fuse 7 Lower clamping plate 4 Emergency S...

Страница 5: ...N the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Factory settings 4 00 Minute Button II Mixing cycle II Factory settings 6 00 Minute Button III Mixing...

Страница 6: ...e corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures ATTENTION...

Страница 7: ...ating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Saf...

Страница 8: ...bvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorized modifica...

Страница 9: ...re taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can reduce residual risks 4 Equipment Description The biax...

Страница 10: ...e legs 1 5 3 Transport rollers The mixer is equipped with two transport rollers on the bottom of the housing These transport rollers can be made to protrude out of the mixing compartment by turning a...

Страница 11: ...mixing vessels To place the container proceed as follows Unlock and open the door by pushing the DOOR button Unlock the lower clamping table 7 by pressing the locking lever 8 to the left and pulling i...

Страница 12: ...done working switch the machine off at the mains 3 6 6 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pr...

Страница 13: ...ntainer is defect Container is unstable Check clamping pressure if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary La...

Страница 14: ...upon interruption of the power supply during the mixing process AUTO With the container clamped or the mixing unit not loaded the mixing unit can be automatically positioned and fixed with the help o...

Страница 15: ...he machine from the mains by pulling out the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 4 Fuses on the device 7 4 1 Device fuse If line voltage is avai...

Страница 16: ...h dry run ball bearings If you clean the machine with a high pressure washer the lubricant is washed out from the ball bearings and they run try Never clean the machine with a high pressure washer or...

Страница 17: ...safety equipment and electrical equipment is to verify and document after the repair Only use original spare parts Do not modify or change safety related parts Any additional components added may not...

Страница 18: ...nt any damages through outside impacts during storage If necessary use cardboard and other packaging material Secure the machine against unintentional tilting and instability 9 2 Disposal The transpor...

Страница 19: ...fuse 10 AT Line fuse 16 A C RCD Typ B Speed of mixing unit 630 rpm Mixing weight max 12 5 kg Container height 90 300 mm Container diameter max 300 mm Ambient temperature 5 30 C Machine weight 189 kg N...

Страница 20: ...VISCO 550 Collomix GmbH 20 Version 1 1 17 10 2 Dimensions...

Страница 21: ...rmation from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 2016 06 01 Alexander Essing Managing Director Manufacturer Collomix GmbH Daimlerstr 9 85080...

Страница 22: ...VISCO 550 Collomix GmbH 22 Version 1 1 17...

Страница 23: ...Collomix GmbH VISCO 550 Version 1 1 17 23...

Страница 24: ...VISCO 550 Collomix GmbH 24 Version 1 1 17 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Отзывы: