Manufacturer:
Collomix GmbH
Daimlerstrasse 9
85080 Gaimersheim
Germany
Rev. 2 / 16
Care and maintenance
Replacing the lamellar ring
Warranty
►
Always disconnect the mains power plug be-
fore carrying out any work on the device, spe-
cifically when changing the grinding tool!
►
The air vents must be kept clean and clear to
ensure sufficient cooling.
Blocked air vents will
lead to the destruction of the machine. Regular-
ly clean the ventilation openings with a vacuum
cleaner.
►
Repairs must only be carried out by authorised
workshops or by the Collomix Service depart-
ment.
►
Only use original Collomix accessories and
spare parts.
The manufacturer offers a product warranty within
the scope of the delivery terms and in accordance
with legal/ country-specific guidelines. Please in-
clude your payment receipt or delivery note with
any warranty claims.
Any repairs carried out by third parties shall re
-
lease us from any warranty obligation. Please re-
turn the machine to us if you detect any irregulari-
ties.
Complaints/ claims can only be considered if
the device is delivered to the Collomix Service de-
partment in a complete and undismantled state.
Any damage resulting from normal wear, over
-
load, improper handling, non-approved accesso-
ries or insufficient maintenance shall be exempt
from the warranty.
Any structural or functional changes to the ma
-
chine not authorised by us shall result in the invali-
dation of the warranty as well as the declaration
of conformity.
Disposal
The accumulated grinding dust may contain harm
-
ful substances. Do not dispose of the dust through
general household waste but at a collection point
for special waste.
The device, accessories and packaging should be
introduced into an environmentally friendly recy-
cling system.
Render any old power tools unserviceable
by removing the power supply cable.
Do not dispose of power tools through
general household waste.
Follow the national regulations for correct collec-
tion and recycling of old power tools, packaging
and accessories.
Subject to change without notice
See Fig. B1 - B4
►
Replace a worn lamellar ring early enough to
ensure op琀椀mised dust extrac琀椀on and the safety
of the operator.
►
Remove the cup wheel to replace the lamellar
ring. Use a universal pliers to pull the lamellar
ring from its holder.
►
Press the new lamellar ring into the clamping
bracket by hand. Make sure that the ring 昀椀ts
琀椀ghtly around the hood. Lubricate the rubber
element with a li琀琀le soapy water to facilitate
inser琀椀on.
Fault tracing
The electronic signal indicator (12) lights up and
the on-load speed decreases.
Motor temperature
is too high. Let the device run at idle speed un琀椀l
the indicator goes out.
The electronic signal indicator (12) 昀氀ashes and the
device is not running.
The restart protec琀椀on was
triggered, interrup琀椀ng the power supply. Switch
the device o昀昀 and on again.