SAFETY PRECAUTIONS

DANGER:

The pump drive is intended for installation in a Class
1 Division 1 Group D hazardous (classified) locations
and must be installed by a qualified electrician per
the National Electrical Code ANSI/NFPA 70. Incorrect
installation of this product can result in the explo-
sive ignition of flammable vapors and liquids which
may be present.

WARNING: To prevent ignition of hazardous atmospheres, this

system must not be installed in an area where vapor
or gases having an ignition temperature less than
280°C are present.

CAUTION:

Failure to wire the system in the manner prescribed
can result in premature failure of the mechanical
speed reduction system and will result in voiding
the warranty.

   WARNING: PRODUCT USE LIMITATION

These products are not designed for, nor intended for use in
patient connected applications; including, but not limited to,
medical and dental use, and accordingly have not been sub-
mitted for FDA approval.

ii

Untitled-1

2/17/04, 7:27 AM

4

Содержание Masterflex 7583-50

Страница 1: ...DUTY PUMP DRIVES Cole Parmer Instrument Co 625 East Bunker Court Vernon Hills Illinois U S A 60061 1844 800 MASTERFLEX 627 8373 847 247 2929 Fax www masterflex com e mail techinfo coleparmer com A 12...

Страница 2: ...Untitled 1 2 17 04 7 27 AM 2...

Страница 3: ...ION 1 SETUP AND DRIVE OPERATION 2 Wiring 2 GENERAL INSTRUCTIONS 3 OPERATING INSTRUCTIONS 4 PUMP MOUNTING 5 Add On Head Capacity 6 MAINTENANCE 6 Cleaning 6 Service Parts 6 Lubrication 6 SPECIFICATIONS...

Страница 4: ...which may be present WARNING To prevent ignition of hazardous atmospheres this system must not be installed in an area where vapor or gases having an ignition temperature less than 280 C are present C...

Страница 5: ...MASTERFLEX L S and MASTERFLEX I P Pump Heads with standard short shafts Ad ditional MASTERFLEX Pump Heads with standard short shafts may be used in tandem The pump speed can be varied from 10 to 430 r...

Страница 6: ...plicable local codes The motor must be wired such that the output shaft of the MOTOR rotates in a clockwise direction when facing the motor shaft See the wiring diagram below 2 WIRING DIAGRAM For Mode...

Страница 7: ...ting plate opening Then select the appropriate adapter for the pump you wish to drive and slip it into the rubber sleeve and seat it firmly see Figure 2 The pump mounting plate which is mounted to the...

Страница 8: ...minimize the starting load it is recommended that the system be at approximately zero speed lever fully CW prior to starting the motor Once the motor has started move the lever to increase speed to t...

Страница 9: ...ERFLEX L S and MASTERFLEX I P pumps All of the MASTERFLEX pumps mount in a vertical orientation See Figure 3 Orient the tang of the pump you wish to drive with the drive adapter and install the pump t...

Страница 10: ...L S Drive Adapter B 3545 Rubber Coupling Sleeve B 3434 Coupling End 3 8 in Bore Speed Reducer B 3546 Coupling End 5 8 in Bore Motor B 3433 Coupling End 3 4 in Bore Motor European B 3676 Lubrication T...

Страница 11: ...nce Painted steel Operating Voltage Frequency 115V AC nominal 57 63 Hz 90 130V AC 4 7 A AC Power Rating 1 4 hp 190W Output Speed Range 10 to 430 rpm Direction of Rotation Clockwise Speed Regulation 10...