background image

WARRANTY

Use only MASTERFLEX precision tubing with MASTERFLEX
pumps to ensure optimum performance. Use of other tubing may
void applicable warranties.

The Manufacturer warrants this product to be free from significant de-
viations from published specifications. If repair or adjustment is neces-
sary within the warranty period, the problem will be corrected at no
charge if it is not due to misuse or abuse on your part, as determined
by the Manufacturer. Repair costs outside the warranty period, or those
resulting from product misuse or abuse, may be invoiced to you.

The warranty period for this product is noted on the Warranty
Card.

PRODUCT RETURN

To limit charges and delays, contact the seller or Manufacturer for au-
thorization and shipping instructions before returning the product, ei-
ther within or outside the warranty period. When returning the product,
please state the reason for the return. For your protection, pack the
product carefully and insure it against possible damage or loss. Any
damages resulting from improper packaging are your responsibility.

TECHNICAL ASSISTANCE

If you have any questions about the use of this product, contact the
Manufacturer or authorized seller.

8

Printed in U.S.A.

020599

Untitled-1

2/17/04, 7:27 AM

12

Содержание Masterflex 7583-50

Страница 1: ...DUTY PUMP DRIVES Cole Parmer Instrument Co 625 East Bunker Court Vernon Hills Illinois U S A 60061 1844 800 MASTERFLEX 627 8373 847 247 2929 Fax www masterflex com e mail techinfo coleparmer com A 12...

Страница 2: ...Untitled 1 2 17 04 7 27 AM 2...

Страница 3: ...ION 1 SETUP AND DRIVE OPERATION 2 Wiring 2 GENERAL INSTRUCTIONS 3 OPERATING INSTRUCTIONS 4 PUMP MOUNTING 5 Add On Head Capacity 6 MAINTENANCE 6 Cleaning 6 Service Parts 6 Lubrication 6 SPECIFICATIONS...

Страница 4: ...which may be present WARNING To prevent ignition of hazardous atmospheres this system must not be installed in an area where vapor or gases having an ignition temperature less than 280 C are present C...

Страница 5: ...MASTERFLEX L S and MASTERFLEX I P Pump Heads with standard short shafts Ad ditional MASTERFLEX Pump Heads with standard short shafts may be used in tandem The pump speed can be varied from 10 to 430 r...

Страница 6: ...plicable local codes The motor must be wired such that the output shaft of the MOTOR rotates in a clockwise direction when facing the motor shaft See the wiring diagram below 2 WIRING DIAGRAM For Mode...

Страница 7: ...ting plate opening Then select the appropriate adapter for the pump you wish to drive and slip it into the rubber sleeve and seat it firmly see Figure 2 The pump mounting plate which is mounted to the...

Страница 8: ...minimize the starting load it is recommended that the system be at approximately zero speed lever fully CW prior to starting the motor Once the motor has started move the lever to increase speed to t...

Страница 9: ...ERFLEX L S and MASTERFLEX I P pumps All of the MASTERFLEX pumps mount in a vertical orientation See Figure 3 Orient the tang of the pump you wish to drive with the drive adapter and install the pump t...

Страница 10: ...L S Drive Adapter B 3545 Rubber Coupling Sleeve B 3434 Coupling End 3 8 in Bore Speed Reducer B 3546 Coupling End 5 8 in Bore Motor B 3433 Coupling End 3 4 in Bore Motor European B 3676 Lubrication T...

Страница 11: ...nce Painted steel Operating Voltage Frequency 115V AC nominal 57 63 Hz 90 130V AC 4 7 A AC Power Rating 1 4 hp 190W Output Speed Range 10 to 430 rpm Direction of Rotation Clockwise Speed Regulation 10...