background image

INTRODUCTION AND GENERAL DESCRIPTION

The Hazardous Duty MASTERFLEX Drive System Model 7583-50 con-
sists of a fixed speed 120V, single phase, 60 Hz motor, a variable me-
chanical speed reducing control, and a pump mounting bracket with
the appropriate drive adapters for MASTERFLEX

®

 L/S

®

 and

MASTERFLEX

®

 I/P

®

 pumps.

Model 7583-52 is identical to Model 7583-50 except that the unit is
supplied without a motor, this allows the customer to furnish the motor
for a specific application.

The pump mounting plate will accept all MASTERFLEX

®

 L/S

®

 and

MASTERFLEX

®

 I/P

®

 Pump Heads with standard (short) shafts. Ad-

ditional MASTERFLEX Pump Heads with standard (short) shafts may
be used in tandem. The pump speed can be varied from 10 to 430 rpm.
The pump rotates in one direction only, clockwise.

For Model 7583-52 to be acceptable for use in a hazardous (classified)
location, the motor supplied by the customer must be UL listed for use
in Class 1 Group D locations. The system is set up to accept a NEMA
56 frame motor without requiring modification.

Couplings are supplied to connect the motor to the mechanical speed
reducer. The base is threaded to accept the 1/4-20 mounting hardware
supplied to fasten the motor to the base.

1

Untitled-1

2/17/04, 7:27 AM

5

Содержание Masterflex 7583-50

Страница 1: ...DUTY PUMP DRIVES Cole Parmer Instrument Co 625 East Bunker Court Vernon Hills Illinois U S A 60061 1844 800 MASTERFLEX 627 8373 847 247 2929 Fax www masterflex com e mail techinfo coleparmer com A 12...

Страница 2: ...Untitled 1 2 17 04 7 27 AM 2...

Страница 3: ...ION 1 SETUP AND DRIVE OPERATION 2 Wiring 2 GENERAL INSTRUCTIONS 3 OPERATING INSTRUCTIONS 4 PUMP MOUNTING 5 Add On Head Capacity 6 MAINTENANCE 6 Cleaning 6 Service Parts 6 Lubrication 6 SPECIFICATIONS...

Страница 4: ...which may be present WARNING To prevent ignition of hazardous atmospheres this system must not be installed in an area where vapor or gases having an ignition temperature less than 280 C are present C...

Страница 5: ...MASTERFLEX L S and MASTERFLEX I P Pump Heads with standard short shafts Ad ditional MASTERFLEX Pump Heads with standard short shafts may be used in tandem The pump speed can be varied from 10 to 430 r...

Страница 6: ...plicable local codes The motor must be wired such that the output shaft of the MOTOR rotates in a clockwise direction when facing the motor shaft See the wiring diagram below 2 WIRING DIAGRAM For Mode...

Страница 7: ...ting plate opening Then select the appropriate adapter for the pump you wish to drive and slip it into the rubber sleeve and seat it firmly see Figure 2 The pump mounting plate which is mounted to the...

Страница 8: ...minimize the starting load it is recommended that the system be at approximately zero speed lever fully CW prior to starting the motor Once the motor has started move the lever to increase speed to t...

Страница 9: ...ERFLEX L S and MASTERFLEX I P pumps All of the MASTERFLEX pumps mount in a vertical orientation See Figure 3 Orient the tang of the pump you wish to drive with the drive adapter and install the pump t...

Страница 10: ...L S Drive Adapter B 3545 Rubber Coupling Sleeve B 3434 Coupling End 3 8 in Bore Speed Reducer B 3546 Coupling End 5 8 in Bore Motor B 3433 Coupling End 3 4 in Bore Motor European B 3676 Lubrication T...

Страница 11: ...nce Painted steel Operating Voltage Frequency 115V AC nominal 57 63 Hz 90 130V AC 4 7 A AC Power Rating 1 4 hp 190W Output Speed Range 10 to 430 rpm Direction of Rotation Clockwise Speed Regulation 10...

Страница 12: ...duct misuse or abuse may be invoiced to you The warranty period for this product is noted on the Warranty Card PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for au thor...

Отзывы: