12
D) Disassembling the Beaters / Augers
Remove the beaters / auger assemblies from each
cylinder by pulling straight out of the machine
towards you.
Disassemble each beater / auger by first removing
the rear rubber beater shaft seal.
Next disassemble the center idler from each beater /
auger frame. To remove, pull the idler straight out
of the front of the beater / auger.
Finally, remove the beater / auger end pusher by
pulling straight out of the beater / auger frame.
Remove the three scraper blades from the beater /
auger frame by gently rotating the blade out of the
frame support brackets.
The machine is now completely disassembled. The
removed parts must now be washed, rinsed, and
sanitized.
E) Cleaning Operation
Wash the removed machine parts in luke warm (80-
90 F) water and mild non-foaming detergent. Scrub
each of the parts with the cleaning brushes
provided in the machines spare parts kit.
!! IMPORTANT !!
DO NOT use hot water on any of the plastic parts
as this may result in damaging these parts
.
Using your three-tank sink, wash rinse, and sanitize
all of the disassembled machine parts. Mix the
sanitizing solution to a 200ppm concentration with
warm water. Allow the parts to soak in the
sanitizing solution for 3-5 minutes before
removing. Allow the parts to air-dry on the clean,
sanitized counter at the end of the sink.
DO NOT
towel or sponge dry these parts.
2) Rinse
3) Sanitize
4) Air Dry
1) Wash