Part IX – Technical Information
A)
Refrigeration:
Compressor – Hermetic / Low Temperature
Suction Pressure (Cylinder) – 18-20 psig.
(Mix Tank) – 20-25psig.
Discharge Pressures – 250 to 260psig.
Refrigerant Type – R-404A ONLY
Cooling Type – Air or Water
Cylinder valve type – TXV w/equalizer
Mix tank valve type – AXV
Refrigerant Charge- See Machine Data Plate
B)
Beater / Auger Drive Motors
Motor Type – Leeson - ODP with C flange
Beater Rotation-(facing front of freezer) - CW
H.O.T Amps – 4.8 single phase
3.8 three phase
Minimum Operating Voltage – 200vac.
Maximum Operating Voltage – 240vac.
C) Thermal Overload
Overload Setting – 7.5 Amps (single phase)
5.0 Amps (three phase)
Overload Ranges –5.0– 8.5 amps – single phase
4.5–6.0 amps – three phase
Thermal Overload – Calibrations and
Settings (Top View)
MAN AUT
AMP.
CALIBRATION
ALWAYS IN
R POSITION
C) Proximity Switches
The sensitivity of these switches can be adjusted
with a small screwdriver. The trimmer location is
on the switch body nearest the front panel.
To adjust the sensitivity, you must remove the
switch from its bracket attached to the front panel.
The adjustment screw should be turned very
carefully either in a clockwise direction to increase
the range or counter clockwise to decrease the
range of operation. Each switch should operate
independently of one another except when product
is drawn from the center dispensing handle which
should activate both motors.