15
Once the orings have been installed onto the three
pistons, place a bead of lubricant between the
orings.
Spread the lubricant to lightly coat the piston
surface between and including the orings. This will
ensure free movement of the pistons and dispensing
handles.
Insert the center piston into the center chamber of
the dispensing head. The center piston is identified
with the one piece “H” type oring. When installing,
align the square handle recess with the rectangular
cut out of the head. Repeat this process with both
end pistons.
Turn over the dispensing head and insert the two
large orings into the grooves in the dispensing
head.
Lightly
lubricate the outside of these orings.
Install the dispensing handles onto the head by
placing the rounded side of the metal cam into the
piston notch. Insert the metal retaining rod into the
dispensing head and piston cams. When all three
handles are installed, affix the small oring into the
metal retaining rods oring groove.