CONFIGURATION:
To show the user that the emitter is heating there is a symbol of a thermometer being filled as
follows:
When the room temperature is below the temperature set point the emitter will turn the element
on to raise the room temperature.
5.4.
Temperature display
The room temperature is normally displayed on the TFT display. The set-point temperature is
only displayed when the user attempts to change it; after the setting has been adjusted the dis-
play will revert to the room temperature:
The
comfort
and
eco
set-point temperatures can be modified both from comfort and economy
modes. The comfort and eco mode can be changed within program mode if they are active at
the time (the anti-frost set-point can never be modified).
On the bar of the current time a small triangle is displayed as an index. Only
the icon for the current time mode is displayed on the vertical axis of the bar
chart.
See section 5.5 "Edit day, time and program" to modify the program used in
this mode.
The configuration screen is at the end of the modes sequence, before enter-
ing the initial comfort mode.
You can configure 4 parameters; the active parameter is flashing:
1 - Brightness level at rest,
from 0 to maximum (100%)
2 - Maximum brightness time,
from
1 s to 240 s
3 -
Open Window
function
ON or OFF
4 -
Adaptive start control
function
ON or OFF
To modify a parameter, use the
-
and
+
keys. To move from one parameter to
the next, press the
OK
key. The system exits this mode by pressing the
mode
key at any time, by waiting 30 seconds without pressing any key or by press-
ing the
OK
key on the last parameter.