Modular Variable Optical Attenuator
|
VOA
Blade
Coherent Solutions
|
VOA
Blade (V1.4
)
44
Command
:INPut
[n]:CHANnel
[m]:WAVelength
Syntax
:INPut[n]:CHANnel [m]:WAVelength<wsp><value>[NM|M|MM|UM|PM]
Description
Set the wavelength of the specified input channel
Parameters
<value>: Set to the user wavelength of the channel with the specified units (NM default)
Response
None
Example
INP1:CHAN1:WAV 1310 NM
Command
:INPut
[n]:CHANnel
[m]:WAVelength?
Syntax
:INPut[n]:CHANnel [m]:WAVelength?<wsp>[LIST]
Description
Query the wavelength of the specified input channel
Parameters
LIST: Get a list of the available programmable wavelengths for the specified input channel
If LIST is omitted the returned value will be the currently set wavelength.
Response
Returns the string for the wavelength for the specified channel
Example
INP1:CHAN1:WAV? LIST -> 1310,1490,1550