Installing the MVS-8100M
1
18
Cognex MVS-8100M Hardware Manual
•
One status output line that can be used by your vision processing application.
•
External camera synchronization signals (8100M and 8100M+ only).
•
One to four light modules, such as the Cognex acuLight and UltraLight products,
that allow software-controlled dynamic light adjustment of the scene under a
camera lens. See
Installing Light Control Hardware
on page 23.
Trigger and Strobe Expansion Panel
To connect trigger, strobe, and status lines, use the trigger and strobe expansion panel,
P/N 800-0062. Secure the expansion panel to an unused bus slot position on the PC’s
back panel. A 10-line ribbon cable extends from the expansion panel to the header at
position J1, in the upper right corner of the 8100.
The brown wire in the multi-colored ribbon cable must align with pin 1 on the 8100’s J1
header. Figure 7 shows the expansion panel and the pin numbering of the panel’s
DB-9F connector.
Figure 7.
Expansion panel for 8100’s trigger and strobe connector (P/N 800-0062)
1
5
6
9
Brown wire must connect to pin 1
Pin 1