2
Installing Light Control Hardware
Cognex MVS-8100C Hardware Manual
25
When using one or more light control modules, Cognex strongly recommends setting
jumper J3 with pins 2-3 covered, and using the external 12 V power cable, P/N
300-0175. This is because PCI slots are limited by the PCI standard to providing no more