background image

CODE Flame 384 User’s Manual 

http://www.codelight.com 

3

 

The set of the scanner address 

Flame 384 console distributes the DMX512 address of various scanners with the fixed space of 24 channels. The 

reference is as following: 

Scann

er No. 

Decima

code 

Binary Code Switch 

Scann

er No 

Decima

code 

Binary Code Switch 

Scann

er No 

Decima

code 

Binary Code Switch 

1 001 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

2 025

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

3

049 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

4 073 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

5 097

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

6

121 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

7 145 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

8 169

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

9

193 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

10 217 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

11 241

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

12

265 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

13 289 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

14 313

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

15

337 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

16 361 

1

2

3

4

5

6

7

8

9

ON

DIP

00

1

00

2

00

4

00

8

01

6

03

2

06

4

12

8

25

6

 

 

 

 

 

 

 

 

Since the first address set is different for various scanner manufacturer. There are two ways to express 512 

channels: the first is 000~511, the second is 001~512. The above table is suitable for the product of the second 

way. For the product of the first way, we should subtract one from the above address, and the first bit of the binary 

code switch should be changed from 1 to

 0. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Flame 384

Страница 1: ...User s Manual Ver 1 04 CODE ELECTRONIC CO LTD...

Страница 2: ......

Страница 3: ...the time of the program step can be changed from 0 03s to 180s 48 scanner scenes can be used directly 8 Chases 48 scenes operated at the same time At most 16 scanners can be selected simultaneously T...

Страница 4: ...inside components of the console and make functions failure Scanner console is precision electric equipment Please pay attention to moistureproof protection and dustproof protection And please clean t...

Страница 5: ...032 064 128 256 8 169 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 016 032 064 128 256 9 193 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 016 032 064 128 256 10 217 1 2 3 4 5 6 7 8 9 ON DIP 001 002 004 008 0...

Страница 6: ...1 16 scanner can be chosen from number keyboard HOLD Scanner hold key When the indicating light is on it is a scanner hold state Multi scanner can be manual operated 1 16 Scanner number keys Press the...

Страница 7: ...SINGLE light is off the current section can run multi scenes at the same time 1 16 Scene number key Cooperating with scene section key 16 scene keys can operate A01 A16 B01 B16 C01 C16 48 scenes Using...

Страница 8: ...Y set key Write the X Y control channel number of various scanners to the console then use modulation wheels to control the position of the various scanners LOAD FILE DELETE Import Files Delete key Pr...

Страница 9: ...h the slider to FAST Chase runs faster Push the slider to SLOW Chase runs slower Chase step Time x SPEED percentage the actual running time of the current Chase step The changeable range is 300 30 Whe...

Страница 10: ...tten to the console one by one X axis of 16Bit resolution scanner is controlled by two data channels Y axis is controlled by two data channels too So X Y is controlled by 4 data channels X axis coarse...

Страница 11: ...entation and the smoothness of the moving trace Auto correction to the wrong setting X L no Y L no must be set at the same time That just one is no is a mistake Flame 384 checks and corrects X L Y L t...

Страница 12: ...modulation wheel ST The set range of a slider is 0 255 Whether 8bit or 16Bit X Y scanner the set range of a modulation wheel is 0 999 It represents the moving range of X axis or Y axis For 16Bit scan...

Страница 13: ...hannel can be chosen at the same time 3 Use CHANNELS sliders to set the channel values Use modulation wheel WX and ST to adjust X Y position 4 Press the corresponding number key of the chosen scanner...

Страница 14: ...key press C key in SCENE then press 10 key and ENTER SWITCH key Chase Edit Flame 384 console can save 48 Chases A Chase is a buildup of some Chase steps The concept of Chase step is very similar to t...

Страница 15: ...ansferring from last step to next step Total time for processing is 10s 70 7s 5 Set the channel values of various scanners in the current step manually Use ENTER SWITCH key to change the setting state...

Страница 16: ...NTER SWICTH key to validate Running Running scene Example 1 Single running scene A01 1 Close running scene B and C one by one 2 Press A key to choose A as the current district 3 Press SINGLE key to ma...

Страница 17: ...w the above 4 Chases are running simultaneously Tips If the chosen Chase is empty without Chase step the screen will display Check the various operating parameters of multi Chases running simultaneous...

Страница 18: ...fine channel low 8Bit channel Y H Y axis coarse channel high 8Bit channel Y L Y axis fine channel low 8Bit channel No For 8Bit scanner only X Y coarse channel can be used So the X Y fine channel must...

Страница 19: ...er Strobe 5 PAN SGM GALILEO 6 TILT 1 PAN 2 TILT 3 Color 4 Gobo 5 Shutter 6 Dimmer Trackspot Bond scanner 7 Motor Speed 1 Strobe Fan Speed Lamp on off Reset Fixture 2 Intensity 3 Color 4 Gobo 1 Fixed G...

Страница 20: ...steps in a Chase 100 Chase step time 0 1s 60s Chase gradual change ratio Cross 0 100 Total capability of Chase steps 1600 Chase amount of simultaneous running scanners 8 Music in phase Chase 10 0dB au...

Страница 21: ...CODE Flame 384 User s Manual http www codelight com 19 M E M O CODE Electronic Co Ltd...

Отзывы: