Process of scene edit:
1
.
According to the ways of manual operation, choose scanner and set the various channel values and
X/Y position.
2
.
Press SAVE TO SCENE key, then press scene district key and scene number key. In the end, press
ENTER / SWITCH key to confirm the save.
Example:
If you want to save the current scanner running states to A13 scene, press SAVE TO SCENE key,
then press A key in SCENE, and press 13 key, in the end, press ENTER / SWITCH key.
Tips:
Scene edit can be done at any time. After the various setting to multi scanners, if the art pattern is
what you want, just perform the above step 2. The running states of all scanners can be saved to a scene
number. For instance, using simultaneously running scene B02 and C07 as basic, choose 3 scanners
manually and set the light beam to some position, then save the combination to scene C01. So, run C01
can recur this light art pattern combination.
Copy of Scene
Example: Copy scene A01 to scene C10.
1
.
Press A key in SCENE, then press 1 key. Then the console run A01 scene.
2
.
Press SAVE TO SCENE key, press C key in SCENE, then press 10 key and
ENTER / SWITCH key.
Chase Edit
Flame 384 console can save 48 Chases.
A Chase is a buildup of some Chase steps. The concept of Chase step is very similar to the scene.
A Chase step is made up of the aggregation of each channel value of various scanners, the step time and the
graduate change parameter Cross.
The total capability of the Chase step is 1600. Each Chase can have up to 100 step. In each step of a Chase, the
step time and the gradual change parameter Cross can be set independently. The standard operating speed of a
Chase is decided by the step time and the gradual change parameter Cross of a step. The speed can be adjusted
from 1/3 to 3 times as the standard speed by SPEED slider.
Step time value
The value defines the interval time between the current to the next step. The unit is 0.1s. The changeable
range of Time is 1-600. It means that the minimum time of a step is 0.1s and the maximum is 60s.
Cross value
The value defines the time ratio of the gradual change treatment between two Chase steps. The range of the
value is 0-100%. For instance, in the current step, Time=10, Cross=60% express that the current step will use
1 second and use 40% of this 1 second as stay time, 60% as gradual change treatment time for moving to the
next step.