CODE Flame 384 User’s Manual
http://www.codelight.com
8
Introduction to the rear
Explanation:
There are 2 optical isolated DMX512 output sockets, which have the same signals.
The USB interface is compatible to the USB Drives which meet FAT format, such as USB1.0, USB2.0
and so on
Audio signal input socket is a 1/4” mono socket with –10 ~ 0dB input level. When the plug is connected,
music trigger signal comes from audio input signal. When the plug is pull out, music trigger signal comes
from the environment sound picked by the inside microphone.
Please use the standard fuse. The standard is printed on the backboard.
The power supply must be connected to the earth line to ensure the safety.
Set X/Y channels for scanners
Flame 384 scanner console can control the scanners with 8Bit or 16Bit X/Y resolution.
Before Flame 384 scanner console uses modulation wheel to control the X/Y position of any DMX512 standard
scanner, the address of every scanner must be set and the set control channel number of each scanner must be
written to the console one by one.
X axis of 16Bit resolution scanner is controlled by two data channels. Y axis is controlled by two data channels, too.
So X/Y is controlled by 4 data channels: X axis coarse channel (high 8Bit), X axis fine channel (low 8Bit), y axis
coarse channel (high 8Bit), and Y axis fine channel (low 8Bit). For 8Bit resolution scanner, X/Y is controlled by 2
data channels: X axis coarse channel and y axis coarse channel,
The explanations of the display can be seen in append table 1.
Setting operation of X/Y:
From the User’s Manual of the scanner, whether the scanner is 8Bit X/Y or 16Bit X/Y and the attribute of the
corresponding channel can be known.
1. Press SET X/Y key, the indicating light is on. It is in setting scanner’s X/Y state.
2. Use scanner keyboard to choose scanner.
3. Use
modulation
wheel
WX
to choose edit item.
4. Use
modulation
wheel
ST
to choose the value of the corresponding channel, range: 1-16, no.
5. Repeat step 2-4 to set X/Y of the other scanners.
6. Press SET X/Y key to quit the edit state.
For example:
Some 8Bit
scanner
X=5, Y=7.
Item Value
X-H 5
X-L no
Y-H 7
Y-L no
Some
16Bit
scanner
X coarse
channel=5,
X fine channel =6,
Y coarse
channel=7,
Y fine channel=8.
Item
Value
X-H 5
X-L 6
Y-H 7
Y-L 8