![Cochran Nemesis IIa NITROX Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/cochran/nemesis-iia-nitrox/nemesis-iia-nitrox_user-manual_2632969073.webp)
73
Missed Deco. Time: This is the remaining decompression time after the dive, shown
in hours and minutes. It should read 0:00 on all no-decompression dives and all
emergency decompression dives where the required decompression stops were
completed. Should you omit any decompression stop time, the remaining omitted
time will be displayed here.
Maximum Deco. Time: This is the maximum amount of time you spent in emergency
decompression, shown in hours and minutes.
Missed Ceiling: This is the deepest stop not satisfied while you were in decompres-
sion. As with Missed Deco Time, this should be "0" on all decompression dives
where the required decompression stops were completed.
Maximum Ceiling: This is the deepest ceiling that was required for decompression
during the dive.
This Dive's Warnings: This is the total number of warnings that were issued by the
computer during the dive.
Tank Size: This the total volume of the tank(s) that you entered for this dive, to be used
in workload calculations.
Sea/Fresh Water: This identifies they type of water in which the dive was made.
Maximum Ascent Rate: This is the fastest ascent rate recorded during the dive.
Maximum A/R Depth: This is the depth at which the maximum ascent rate occurred.
Maximum A/R Bot.Time: This is the bottom time recorded when the maximum ascent
rate occurred.
Minimum Temperature: This is the coldest water temperature recorded during the
dive.
Average Temperature: This is the true average water temperature calculated for the
total dive.
Maximum Temperature: This is the warmest water temperature recorded during the
dive.
Avg Breath Parameter: This is the average breathing parameter for the dive.
Max Breath Parameter: This is the maximum breathing parameter calculated during
the dive.
O2 Mix Switch Depth: This is the depth recorded at the time of the switching to Mix 2.
O2 Mix Switch B. Time: This is the bottom time recorded at the time of the switching
to Mix 2.
Maximum PO2: This is the largest PO2 level recorded during the dive.
Содержание Nemesis IIa NITROX
Страница 7: ...7 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 31: ...31 SECTION III EXPLANATIONS...
Страница 45: ...45 SECTION IV CARE AND MAINTENANCE...
Страница 49: ...49 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 50: ...50 SECTION V TECHNICAL SPECIFICATIONS...
Страница 53: ...53 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 54: ...54 SECTION V ACCESSORIES...
Страница 59: ...59 Depth Limit for Mix 3 Activation nitrox Cylinder Size in Liters Elapsed Bot Time for Mix 3 Activation nitrox...
Страница 79: ...79...