![Cochran Nemesis IIa NITROX Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/cochran/nemesis-iia-nitrox/nemesis-iia-nitrox_user-manual_2632969037.webp)
37
Remain Time DEC:
Emergency Decompression Mode: The time displayed will be dependent upon how
the dive computer has been setup. The information displayed will be either:
Total time to complete all required decompression - or -
Time Remaining at each individual stop - or -
Alternating between total and stop time.
If the alternating option is selected, each time is displayed for 2 seconds.
Logbook Mode: If you are viewing an Emergency Decompression dive, the total
required decompression time would be displayed followed by the DEC leg-
end.
Surface Time:
Surface Mode or Gauge Mode: Surface time is displayed in hours and minutes from
the time the TU is turned on or at the end of a dive when ascending above
three feet. Surface times from 0:00 to 17:03 will be displayed.
Tank:
Surface Mode , Subsurface Mode, Emergency Decompression Mode, or Gauge Mode:
The numbers under the TANK legend are used to display the current tank
pressure in one psi increments.
Predive Prediction Mode: If the amount of air remaining in your tank allows five min-
utes or less of bottom time for a given depth during the Predive Prediction
Mode, the tank digits will flash. This flashing will only occur for the predicted
depths which apply.
Logbook Mode: During the first three seconds of display, the accumulative dive num-
ber is shown, then replaced by the ending tank pressure for the dive profile
viewed.
CNS/OTU Toxicity Display: The numbers under the TANK legend indicate the current
CNS Toxicity percentage.
O2 Mix Display: On this display the number under the DEPTH legend is used to display
the user programmed percentage of oxygen in mix #1. This value is displayed
as a factor of 10. For example an oxygen percentage of 21.5 percent would be
displayed as 215.
Battery/Altitude Display: In the Battery/Altitude Display, the number under the TANK
legend are used to display altitude rounded to the nearest thousands of feet
above sea level. For example, if under the TANK legend you see 4, the alti-
tude calculated would be between 3600 feet and 4500 feet
Temp:
Surface Mode: The current temperature that is calculated by the TU will be displayed.
Subsurface Mode: This is the water temperature calculated by the TU.
Logbook Mode: This is the average water temperature recorded for the viewed profile
Содержание Nemesis IIa NITROX
Страница 7: ...7 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 31: ...31 SECTION III EXPLANATIONS...
Страница 45: ...45 SECTION IV CARE AND MAINTENANCE...
Страница 49: ...49 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 50: ...50 SECTION V TECHNICAL SPECIFICATIONS...
Страница 53: ...53 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 54: ...54 SECTION V ACCESSORIES...
Страница 59: ...59 Depth Limit for Mix 3 Activation nitrox Cylinder Size in Liters Elapsed Bot Time for Mix 3 Activation nitrox...
Страница 79: ...79...