Chapter 5: Installation check and test
Test the system with easyMail
77
5555
Install
ation che
ck
and
SAILOR 6194 and one for the SAILOR 3027.
First bar green: easyMail has connected to the SAILOR 6194. Red: No
connection between easyMail and SAILOR 6194
Second bar green: easyMail has connected to the SAILOR 3027. Red: No
connection between easyMail and SAILOR 3027.
5.3.2 Distress test (only SAILOR 6150 Non-SOLAS
System)
To verify the connection to the SAILOR 3042E alarm panel, you can make a
Distress test. Do as follows:
1. In the easyMail application, click
Distress
>
Distress Test Mode
.
A popup shows that the system is in Distress test mode.
2. Press and hold the alert button on the SAILOR 3042E for at least 5
seconds.
During this time the button light flashes and the buzzer sounds. After 5
seconds the red light goes steady on and the buzzer is silent.
3. To clear alarm indications, select
Distress
>
Reset alarms/latest
Distress info
, or press and then release the Clear button (if installed).
The button light should go off.
4. To exit Distress test mode, click
Cancel
in the
Distress test mode
popup.
Important
Never test the installation by sending an alert on-air!
If an alert is sent by mistake, inform the relevant authorities
immediately.
Содержание SAILOR 6120
Страница 1: ...SAILOR 6120 30 40 50 Installation manual...
Страница 2: ......
Страница 3: ...i SAILOR 6120 30 40 50 Installation manual Document number 98 154541 A Release date November 15 2017...
Страница 12: ...List of tables x...
Страница 31: ...Chapter 2 Install the system Install the SAILOR 3027 19 2222 Install the system Vertical pole Horizontal pole...
Страница 96: ...Chapter 5 Installation check and test 84 Test the system with SAILOR 6018...
Страница 116: ...98 154541 A www cobham com satcom...