Chapter 3: Connect the system
Ground the units
29
3333
Co
nn
ec
t th
e
sy
st
em
As an alternative to the NMEA connectors you may use a CAN connection
box, (part number 406208A).
For a list of additional cables and connectors available from Cobham
SATCOM, see
If you are using a SAILOR 6194 Terminal Control Unit, refer also to the
manual
SAILOR 6194 Terminal Control Unit, Installation and user manual
[3].
3.2 Ground the units
Make sure you have a suitable grounding location for grounding the units,
preferably close to the power supply. See page 16 in the section
of the SAILOR 3027 mini-C terminal
3.2.1 SAILOR 3027 mini-C terminal
You may use a special CAN cable, containing only the power wires and
shield, to connect to the power supply. Using a T-connector, this cable can
be connected to the full CAN bus.
Connect the shield of the CAN cable to ship ground at the power supply.
Make sure the power supply has a good ship ground connection, e.g.
through the mounting plate and/or chassis.
Important
The shield of the CAN cable from the terminal must be
grounded at the power supply,
not
at the terminal. This is to
ensure that any lightning strike at the terminal will be
directed straight to the ship ground, and away from
equipment operated by personnel.
Содержание SAILOR 6120
Страница 1: ...SAILOR 6120 30 40 50 Installation manual...
Страница 2: ......
Страница 3: ...i SAILOR 6120 30 40 50 Installation manual Document number 98 154541 A Release date November 15 2017...
Страница 12: ...List of tables x...
Страница 31: ...Chapter 2 Install the system Install the SAILOR 3027 19 2222 Install the system Vertical pole Horizontal pole...
Страница 96: ...Chapter 5 Installation check and test 84 Test the system with SAILOR 6018...
Страница 116: ...98 154541 A www cobham com satcom...