Appendix B: Command reference
98-140012-H
SMS remote commands
149
SMS reject responses
Reject Response SMS
Possible Cause
ACT/DEACT PARM PROBLEM
The <IP addr> provided for an ACTIVATE or
DEACTIVATE command is incorrect (for
ACTIVATE, it must be in same subnet as the
EXPLORER 710 IP and not be the
EXPLORER 710 IP; for DEACTIVATE, it must
exist as a local or global IP address in the
existing PDP table).
ATCO ERROR
Unable to send AT command to ATC handler.
COMMAND NOT SUPPORTED
Attempt to use an SMS command not
supported by the EXPLORER 710.
ERROR: TERMINAL BUSY
An ACTIVATE or DEACTIVATE command is
in progress.
INVALID RESTART REQUEST
Attempt to perform restart before
EXPLORER 710 has been running for at least
15 minutes.
INVALID WANMODE REQUEST
The requested WAN mode is not supported
by the EXPLORER 710, or invalid parameters
are used.
INVALID WATCHDOG PING ADDRESS
Entered Ping address is out of range (0.0.0.0
– 255.255.255.254).
INVALID WATCHDOG PING FREQUENCY
Requested Ping Frequency is less than the
minimum (5 minutes).
INVALID WATCHDOG REQUEST
"Ping required" or "wdog enabled" fields
incorrect in remote SMS message, or
watchdog request other than "get"
attempted.
WRONG CONNECTION TYPE(NO DHCP TE)
No DHCP TEs connected to the Remote Unit.
WRONG CONNECTION TYPE(NO STATIC TE) No Static TEs added in Terminal settings.
WRONG CONNECTION TYPE(NO TEs)
No TEs are connected to the Remote Unit.
WRONG PASSWORD
Authentication Failure.
WRONG QOS
Invalid QoS Requested (only a QoS of 1 is
valid).