background image

 

39 

SECTION 01  
INTRODUCTION & IMPORTANT SAFETY INSTRUCTIONS  

INTRODUCTION 

Congratulations! You have purchased a Spa with an EcoClean system, 
one of the most technologically advanced spa sanitation systems in the 
world. 

IMPORTANT SAFETY INSTRUCTIONS 

READ AND FOLLOW ALL INSTRUCTIONS 

 
EQUIPMENT RELATED, INSTALLATION AND GENERAL USE:  
Installation of all EcoClean models 
 
When installing and using the EcoClean unit, basic safety precautions 
must always be followed, including the following: 

 

WARNING

 Risk of electrical shock. Plug the unit into an ap-

proved G.F.C.I. electrical outlet (110VAC ONLY). 
 

WARNING

 Do not use spas or hot tubs unless all suction 

grates are installed to prevent body and hair entrapment. 
 

WARNING

 To reduce the risk of electric shock, replace dam-

aged cords immediately. 
 

WARNING

 To reduce the risk of electric shock, do not use 

extension cords to connect unit to electrical supply. 

 

 

People using medication and/or having an adverse medical history should 

consult a physician before suing a spa or hot tub. 

 

People with infectious diseases should not use a spa or hot tub. 

 

The maximum spa water usage temperature is 40°C (104°F). Duration in spa 

water at 40°C (104°F) should not exceed 15 minutes. Lower water tempera-

tures are recommended for young children and when spa use exceeds 10 

minutes. 

 

Water temperatures in excess of 40°C (104°F) may be dangerous to your 

health. 

 

Pregnant or possibly pregnant women should consult a physician before using 

a spa or hot tub. 

 

Since excessive water temperatures have a high potential for causing fetal 

damage during the 1st trimester of pregnancy, pregnant or possibly pregnant 

women should limit the spa water temperatures to 38°C (100°F). 

 

The use of alcohol, drugs, or medication before or during spa or hot tub use 

may lead to unconsciousness with the possibility of drowning. 

 

Obese persons and persons with a history of heart disease, low or high blood 

pressure, circulatory system problems, or diabetes should consult a physician 

before using a spa/hot tub. 

 

Persons using medication should consult a physician before using a spa or hot 

tub since some medication may induce drowsiness while other medication may 

affect heart rate, blood pressure, and circulation. 

 

Do not use a spa or hot tub immediately following strenuous exercise. 

 

Prolonged immersion in a spa or hot tub may be dangerous to your health. 

 

OWNER’S MANUAL 

2017 

WARNING

 To reduce the risk of injury do not permit children to use this 

product unless they are closely supervised at all times. Children should 
not use spa or hot tub without permanent adult supervision. 
 

WARNING

 Risk of Accidental Drowning. Extreme caution must be exer-

cised to prevent unauthorized access by children. To avoid accidents, 
ensure that children cannot use a spa or hot tub. 
 

DANGER

 To reduce the risk of injury, do not remove the suction grates. 

Never operate a spa or hot tub if the suction grates are broken or miss-
ing. Never replace a suction grate with one rated less than the flow rate 
marked on the equipment assembly. 
 

DANGER

 Risk of Electrical Shock. Do not permit any electrical appliance 

such as a light, telephone, radio or television within 1.5m (5 feet) of spa 
or pool. 
 

To avoid injury, exercise care when entering or exiting the spa or hot tub. 
 

WARNING

 The use of alcohol or drugs can greatly increase the risk of 

fatal hyperthermia in hot tubs and spas. 
 
Consult your spa/hot tub manufacturer’s manual for the proper adjust-
ment of water temperature. Prolonged immersion in hot water may in-
duce hyperthermia. Hyperthermia occurs when the internal temperature 
of the body reaches several degrees above the normal body temperature 
of 37°C (98.6°F). Hyperthermia symptoms include drowsiness, lethargy, 
and an increase of internal body temperature. 
 

The effects of hyperthermia include: 

 

unawareness of impending hazard 

 

 

physical inability to exit the spa 

 

failure to perceive heat 

 

 

fetal damage in pregnant women 

 

failure to perceive the need to exit the spa/hot tub 

 

 

unconsciousness and danger of drowning 

 

EXPOSURE TO DIRECT SUNLIGHT 

Spas that are exposed to large amounts of direct sunlight will also burn 
through sanitizer at a higher rate. Ensure that the cover is closed when 
the spa is not in use and that the air control dials on the topside of the 
spa are also closed as this too will reduce your sanitizer levels if left on. 

SECTION 02 
SPECIFICATIONS 

The operation of the Eco Clean system is very dependant of the water 
chemistry in your spa. Proper spa water conditions need to be in place to 
ensure that the system will perform at its best. 
 
The EcoClean is designed to maintain the sanitizer level while the spa is 
not in use. If the bather load increases and/or the temperature are always 
set to 40°C (104°F), then there may be the need to add sanitizer as a 
supplement.The EcoClean runs in 30 minute cycles. There is an Output 

Содержание Coast Spas with hydro Cyclonic Filtration Sydtem

Страница 1: ...1 VERSION 01152016 Coast Spas Manufacturing Inc 6315 202 Street Langley BC Canada 604 514 8111 info coastspas com www coastspas com ...

Страница 2: ...e 8 Draining Winterizing Page 8 Filter Maintenance Page 9 Water Quality Maintenance Page 9 10 MicroSilk Information Page 10 Water Clarity Troubleshooting Page 11 Product Care Guide Page 12 13 Glossary of Terms Page 13 14 Troubleshooting Guide Page 15 16 Spa Controls Page 17 18 Coast Elite Series Controls early 2016 Page 19 27 Coast Luxury Series Controls Page 28 37 Installation Service Information...

Страница 3: ...3 ...

Страница 4: ...accessories The Coast Connect Universal Fitting is installed flush to the spa floor and supplies both light and water to the connected accessory Image installed Accessory Connection Place male accessory connection into female Universal Fitting Twist clockwise to connect and secure Twist counter clockwise to disconnect and remove ...

Страница 5: ...5 ...

Страница 6: ...6 ...

Страница 7: ...y of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a hot tub CAUTION Risk of Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the OWNER S MANUAL 2017 normal body temperature of 98 6 F 37 C The symptoms of hyperther mia include drowsiness lethargy and an increas...

Страница 8: ...el surface so the spa weight is supported uniformly We recommend no less than a 3 93 mm thick concrete slab Wood decking or balconies must be con structed to support 150 pounds per square foot 730 kg m Refer to local and current building codes in your area Consult an engineer for live loads in your area Should your new spa need to go through a gate the opening should be a minimum of 48 inches and ...

Страница 9: ... minerals and or oils Rinse filter thoroughly before installing Clean o ring on filter lid and apply a light film of silicone lubricant to the o ring Do not use a petroleum based lubri cant as it could damage the o ring Consult your dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only OWNER S MANUAL 2017 N...

Страница 10: ...f the water Your Authorized Dealer can advise you on the use of these additives OWNER S MANUAL 2017 MICROSILK If your hot tub is equipped with a MicroSilk generator you can take ad vantage of some incredible health and appearance benefits Find ex panded information below on the Microsilk system benefits and opera tion ABOUT MICROSILK MicroSilk produces a silky white cloud of micro bubbles that are...

Страница 11: ...o low pH is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust pH Shock spa with sanitize...

Страница 12: ...ediately until the water has been restored to suggested conditions Do not sit on the pillows OWNER S MANUAL 2017 Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa HOT TUB INTERIOR Your hot tub has a fiberglass reinforced acrylic shell Generally dirt and stains will not ...

Страница 13: ... the fluid used in cigarette lighters Use sparingly then immediately apply conditioner to that area GLOSSARY OF TERMS AIR CONTROL VALVE Mounted generally on the lip of the spa it in duces warm air from the equipment enclosure into the jet stream through venturi action WATER DIVERTER VALVE The large diverter is used to divert water to various seats in the spa OWNER S MANUAL 2017 ON OFF DIVERTER VAL...

Страница 14: ...ge ADJUSTABLE CLUSTER JET Our adjustable high intensity hydro therapy jet DIRECTIONAL JET Provides a straight flow for a therapeutic massage ROTATIONAL JET Provides a Uni directional circular therapeutic mas sage MASSAGE JET Delivers massage in staccato bursts over a narrow focused area VOLCANO WHIRLPOOL JET high output jet designed for foot and leg massage LAMINAR FLOW WATER FEATURE A thin stream...

Страница 15: ...Pump running constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Deal...

Страница 16: ...periods of time in cold weather cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No...

Страница 17: ...e panel however you will still be able to control the high speed setting The ozone generator if installed will activate anytime low speed is run ning AUX PUMP 2 If an additional pump or blower is installed Press Aux to turn the de vice on If your additional device is a dual speed pump pressing Aux OWNER S MANUAL 2017 again will activate the pumps high speed Pressing Aux again will turn off the dev...

Страница 18: ...e a temporary condition If flashing by itself spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If prob lem persists contact your dealer or service organization LF Persistent low flow proble...

Страница 19: ...Press any button on the screen to wake the panel up NAVIGATION Navigating the entire menu structure is done with the 5 buttons on the control panel When a text item changes to white during navigation that indicates the item is selected for action Operating or changing a selected item is generally done with the center or Select button The only item that can be changed on the left side of the Main S...

Страница 20: ...s where all programming and other spa behaviors are controlled This screen has several features that can be acted on directly These features include Temp Range Heat Mode and Invert Panel When one of these items is highlighted the Select Button is used to toggle between two settings All other menu items with an arrow point ing to the right go to another level in the menu PRESS AND HOLD If an Up or ...

Страница 21: ...ng the heater under low flow or no flow conditions Nothing comes on auto matically but the pump s can be energized by selecting the Jet but tons If the spa has a Circ Pump it can be turned on and off by press ing the Circ Pump button during Priming Mode In addition if the spa has a Circ Pump it can be activated by pressing the dedicated Light button during Priming Mode Manually exit Priming Mode b...

Страница 22: ... one filter cycle that will run in the evening assuming the time of day is properly set when energy rates are often lower The filter time and duration are programmable A second filter cycle can be enabled as needed FREEZE PROTECTION If the temperature sensors within the heater detect a low enough tem perature then the water devices automatically activate to provide freeze protection The water devi...

Страница 23: ...manner with each button press RESTRICTING OPERATION The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access ...

Страница 24: ...lighted the detail for that item is displayed at the bottom of the screen Software ID SSID Displays the software ID number for the System System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration file Heater Wattage as Configured in Software Displays a heat...

Страница 25: ...ze pro tection is needed M0XX is a Message Code Codes like this will be seen in the Fault Log Some messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message Press the message text to reset the message SENSOR RELATED MESSAGES SENSORS ARE OUT OF SYNC M015 The temperature sensors MAY be out of sync by 3 F Call for Service SENSORS ARE OUT ...

Страница 26: ...sionally to maintain proper spa function and sanitary con ditions Additional messages may appear on specific systems Reminder messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message Press the message text to reset the message Warning Qualified Technician Required for Service and Installation BASIC INSTALLATION AND CONFIGURATION GUIDE...

Страница 27: ...ite du disjoncteur differentiel avant d utiliser differentiel avant d utiliser le bain Lire la notice technique Lorsque l appareillage est installe dans une fosse on doit assurer un drainage adequat Employer uniquement a l interieur d une cloture CSA Enclosure 3 Connecter uniquement a un circuit protege par un disjoncteur differen tiel de Class A Afin d assurer une protection permanente contre le ...

Страница 28: ...ns time out and revert to the main screen after 30 sec onds of no activity OWNER S MANUAL 2017 The only item that can be changed on the left side of the Main Screen is the Set Temperature Touch either the set temperature line or the water temperature to go to the Set Temperature screen MESSAGES At the bottom of the screen messages may appear at various times Some of these messages must be dismisse...

Страница 29: ...ave changed the value on that screen If the screen times out due to no activity it will act like Cancel When you see only this button whether it is labeled or not it means Back or Exit It appears on editing screens before you have changed any value as well as on all other screens OWNER S MANUAL 2017 PAGE UP DOWN If an Up or Down button is shown and pressed when in a Menu List the list can be scrol...

Страница 30: ...il the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn the heater pump off OWNER S MANUAL 2017 CIRCULATION MODE If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa will maint...

Страница 31: ...re polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from the panel however the high speed may be started CIRCULATION PUMP MODES If the system is equipped with a circ pump it will be configured to work in one of three different ways 1 The circ pump operates continuously 24 hours with the exception of turning off for 30 minu...

Страница 32: ... may be manufactured with Circ Pump settings that allow programming filtration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode details PURGE CYCLES In order to maintain sanitary conditions as well as protect against freez ing secondary water devices will purge water from their respe...

Страница 33: ...t says On or Panel if it says On than press in the middle of the screen for at least 5 seconds OWNER S MANUAL 2017 SCENES WHAT ARE SCENES Scenes are stored combinations of equipment states For example if you want to have Pump 1 at high speed and Pump 2 at low speed and the Light ON you could store that in a Scene and recall this combination at any time STORING A SCENE Press a Scene number and hold...

Страница 34: ...0XX is a Message Code Codes like this will be seen in the Fault Log ADDITIONAL SETTINGS PREFERENCES The Preferences Menu allows the user to change certain parameters based on personal preference TEMP DISPLAY Change the temperature between Fahrenheit and Celsius TIME DISPLAY OWNER S MANUAL 2017 Change the clock between 12 hr and 24 hr display REMINDERS Turn the reminder messages like Clean Filter O...

Страница 35: ...e GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the above menu Passed should appear after the Reset line is selected on the GFCI screen WARNING On those systems that automatically test the GFCI within 1 to 7 d...

Страница 36: ...for Service MISCELLANEOUS MESSAGES COMMUNICATIONS ERROR The control panel is not receiving communication from the System Call for Service TEST SOFTWARE INSTALLED The Control System is operating with test software Call for Service OWNER S MANUAL 2017 F OR C IS REPLACED BY T The Control System is in Test Mode Call for Service M0XX is a Message Code Codes like this will be seen in the Fault Log SYSTE...

Страница 37: ...upter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment OWNER S MANUAL 2017 CSA ENCLOSURE TYPE 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer to Installation and Safety Instructions provided by the spa manufacturer Warning People with infectious diseases should not use...

Страница 38: ...ater in your spa MODEL ST1 REGISTRATION NUMBER 27899 02 PEST CONTROL PRODUCTS ACT SECTION 01 Introduction Important Safety Instructions Health General Hyperthermia Important Information SECTION 02 Specifications SECTION 02 Preparation Monitoring Operation Boost Option Power Supply Cell Installation SECTION 04 Troubleshooting ...

Страница 39: ...t tub may be dangerous to your health OWNER S MANUAL 2017 WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spa or hot tub without permanent adult supervision WARNING Risk of Accidental Drowning Extreme caution must be exer cised to prevent unauthorized access by children To avoid accidents ensure...

Страница 40: ...low the unit to receive power 24hrs a day Once this is connected and pump 1 is running you will see the ozone knob glow with a slight blue green tinge The Eco Clean light will also begin to blink Green for up to 30 seconds During this time the EcoClean is measuring the salt content of the water OWNER S MANUAL 2017 4 If the light stays Green then the unit is now running and converting salt to sanit...

Страница 41: ...DC Plug burned The cell cord plug is not securely pushed onto the power supply allowing moisture to seep into the plug Completely failed cell Ensure that the cell cord plug is pressed completely on the power supply Replace the cell White flakes in the water This occurs when excessive calcium hardness is pre sent in the water being sanitized This should cease after a few days Monitor the pH and adj...

Отзывы: