20
OWNER’S MANUAL
2017
THE SETTINGS SCREEN
ALL EQUIPMENT ACCESS
The Spa Screen shows all available equipment to control, as well as
other features, like Invert, in one easy-to-navigate screen. The display
shows icons that are related to the equipment installed on a particular
spa model, so this screen may change depending on the installation.
The navigation buttons are used to select an individual device. The de-
vice that is chosen is highlighted with a white outline and the text under
the icon changes to white. Once a device is selected, it can be controlled
using the center Select Button. Some devices, like pumps, may have
more than one ON state, so the icon will change to reflect the state that
the equipment is in. Below are some examples of 2-speed Pump indica-
tors.
If the Spa has a Circ Pump, a Circ Pump Icon will appear to indicate its
activity, but outside of Priming Mode, the Circ Pump cannot be con-
trolled directly.
NOTE: The icon for the pump that is associated with the heater (Circ or
P1 Low) will have a red glow in the center when the heater is running.
ONE-PRESS ACTIVATION
The Shortcut Screen requires no navigation. Each button is fixed on a
specific function and can be used as a very simple user interface for the
spa.
Each button function is illustrated in the display and mapped ac-
cording to the manufacturer’s instructions.
PRESSING A “BUTTON”
When instructions are given to “press a button” any of the following can
be done:
• Navigate to the desired item on any Screen. When the desired item is high-
lighted, press the Select Button.
• Press the button for that device while on the Shortcuts Screen, if the device is
one of the 4 functions available.
PROGRAMMING, ETC.
The Settings Screen is where all programming and other spa behaviors
are controlled. This screen has several features that can be acted on
directly. These features include Temp Range, Heat Mode, and Invert
Panel. When one of these items is highlighted, the Select Button is used
to toggle between two settings. All other menu items (with an arrow point-
ing to the right) go to another level in the menu.
PRESS-AND-HOLD
If an Up or Down button is pressed and held when an item in a Menu List
is highlighted, the list can be scrolled quickly from top to bottom. The
scroll bar on the right side of the screen indicates the relative position of
the highlighted item in the list.
DUAL TEMPERATURE RANGES (HIGH VS. LOW)
This system incorporates two temperature range settings with independ-
ent set temperatures. The specific range can be selected on the Settings
screen and is visible on the Main Screen in the upper right corner of the
display. These ranges can be used for various reasons, with a common
use being a “ready to use” setting vs. a “vacation” setting. Each range
maintains its own set temperature as programmed by the user. This way,
when a range is chosen, the spa will heat to the set temperature associ-
ated with that range.
High Range can be set between 80°F and 104°F.
Low Range can be set between 50°F and 99°F.
Freeze Protection is active in either range.
HEAT MODE – READY VS. REST
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the “heater
pump. The heater pump can be either a 2-speed pump (Pump 1) or a
circulation pump. If the heater pump is a 2-Speed Pump 1, READY Mode
will circulate water every 1/2 hour, using Pump 1 Low, in order to main-
tain a constant water temperature, heat as needed, and refresh the tem-
perature display. This is known as “polling.” REST Mode will only allow
heating during programmed filter cycles. Since polling does not occur,