SECTION 2 Installation
1A. Description
The DEL AOP
®
-S described in this manual is designed to provide the
benefits of ozonated and UV sterilized water in an environmentally
safe and effective manner. The high quality, specially engineered
components ensure efficient and reliable performance. As a result
of proper use of the DEL AOP
®
-S, unpleasant effects of traditional
chemical use are virtually eliminated. It is safe and harmless to your
equipment when installed properly.
1B. Specifications
Power Requirements:
110-240V, 50-60 Hz, 1Ø, 0.3 Amp
Water Flow rate:
5-20 GPM
Location Requirements:
Mounting: Wall or post mount in a clean, protected area.
Ambient Temp.: 35°F - 120°F (2°C - 49°C)
2A. Location
Mount in a clean, protected area out of direct sunlight. The unit
must be installed in an outdoor location, or indoors in a forced
air ventilated room, and installed so that the orientation is exactly
as shown in Figure 1. Locate out of reach of sprinklers or drainage
spouts. Mount in the orientation shown in Figure 1, using the two
mounting holes provided inside the enclosure. Allow sufficient
clearance in front for internal access, and above for service of the UV
lamp and quartz tube (13 inches). The DEL AOP-S should be installed
at least one (1) foot above the maximum water level. See Section 2C-3
Check Valve Assembly, for plumbing instructions based on mounting
location.
2B. Wall Mounting
1. Wall mount near pool equipment.
2. Refer to Figure 1 to mark the locations for the two mounting
screws.
3. Install screws (or other hardware appropriate for mounting
surface) through the two mounting holes built into the
enclosure.
Figure 1: Mounting Location & Notations
(cover removed)
Ozone Output
Barb
Bonding Lugs
½” Knockout
Main Power
Wires
Water Outlet
Mounting Holes
(2x)
Water Inlet
Allow Vertical Clearance
for UV Lamp Removal
System Active
Indicator
Air Intake
Filter