SECTION 4 Maintenance & Service
CAUTION:
Follow the directions for safe use and
handling of muriatic acid on the acid bottle label. When
mixing, always add acid to container first then add water.
6. After cleaning the quartz tube, wash it off with water and wipe
dry with a soft towel.
7. Make sure the inside of the quartz tube is dry before installing
the UV lamp.
4D-4. Quartz Tube Installation
1. Place the sealing o-ring on the quartz tube 3/4 inch from the
open end.
2. Insert the quartz tube partially into the quartz tube adapter.
Place the UV lamp retainer over the open end of the quartz
tube and slowly push in until it is touching the quartz tube
adapter.
3. Reinstall the two screws and washers and tighten until the UV
lamp retainer is seated completely against the quartz tube
adapter.
4. Turn on the pool pump and check the joint around the UV
lamp retainer for leaks.
5. If it leaks, please contact Customer Support at 1-800-733-9060.
6. Once you have confirmed that there are no leaks, turn off the
pool pump and install the UV lamp as described in
Section
4D-2.
4E. Troubleshooting
Knowledge of electrical applications is required for troubleshooting.
Contact a certified electrician if you are unsure of your ability to
service the equipment. Improper servicing will void the warranty.
Symptom:
“SYSTEM ACTIVE” indicator not lit when the pool system is
on.
1. No power to the AOP-S from the power source.
a. Check breaker at the power distribution box.
b. Check for loose connections or wiring breaks from the
power distribution box to the AOP-S.
c. The G.F.C.I. has been tripped. Reset the G.F.C.I.