background image

6

3.1.4

 

Setting the Waterfall

For standard pool applications, the waterfall must be installed before the deck and coping. Place the 

waterfall in the notch cut in the bond beam or wall application. Utilize substrate material such as tile, thinset 

or mortar to make sure that the waterfall is level with the top of the upper edge of the bond beam. Fill the 

gaps around the unit and coat the face of the waterfall with concrete or similar material in preparation for 

the tiles or other material. Cut the tile/material to fit under the lip of the waterfall using thinset or similar 

substance to secure in place. Make sure to leave about 1/8” overhang of the waterfall face, after the tiles has 

been installed (Figure 5 & 6). Ensure the waterfall is level front to back and across the length of the fall.  

Complete the electrical installation and plumbing before covering the top deck.

 

Figure 5: Waterfall flow edge overhang – Shown with tile

When installing the final facia to the waterfall whether using tile, stone or other substrate, do not cover the 

access doors.  These will be required for servicing the unit. 

 

Figure 6: Installation of the waterfall unit.

 

.

WATERFALL

Leave about 1/8” overhang 

after tiles are installed

TILE

CONCRETE

Do not cover access doors with tile, stone, or any substrate.

Содержание Brilliant wonders 25677 series

Страница 1: ...INSTALLATION INSTRUCTIONS CMP 25677 SERIES...

Страница 2: ...Qty 2 2 SAFETY Please take a moment to read through the included important safety information Following these safety requirements should prevent any damage to your new LED waterfall or controller WARN...

Страница 3: ...nstructions enclosed with this waterfall It is recommended to keep the unit in its original packaging until the site is prepared for installation NOTE USE ONLY WATER THAT HAS BEEN PROPERLY FILTERED Th...

Страница 4: ...e typically used in concrete When forming an area for installation note that a plumbing and electrical notch must be provided Figure 2 General Dimensions for the install are as follows The foundation...

Страница 5: ...aterfall is capable of accommodating conduit on either side Figure 4 Choose which side to install the electrical PVC pipe Refer to section 3 1 5 if you are planning on changing the electrical output s...

Страница 6: ...the waterfall using thinset or similar substance to secure in place Make sure to leave about 1 8 overhang of the waterfall face after the tiles has been installed Figure 5 6 Ensure the waterfall is l...

Страница 7: ...l A filter strainer is also required between the pump and the waterfall in this plumbing situation Installations requiring more than 60 gallons per minute may require two or more filters to be plumbed...

Страница 8: ...igure 9 shows the recommended optimum flow pattern for a 24 waterfall Plumbing Guideline Chart Use a minimum of 1 1 2 pipe Use a minimum of 2 pipe for runs over 60 Maximum Recommended Flow 1 1 2 Pipe...

Страница 9: ...s shown in Figure 10 CMP ball valve part numbers are 25800 151 000 for 1 and 25800 210 000 for 2 Figure 10 Multi Waterfall Valving NOTE USE ONLY WATER THAT HAS BEEN PROPERLY FILTERED 4 Additional Part...

Страница 10: ...s than 1 5 of the body The LED on my waterfall is only red or blue 1 You may have the incorrect transformer A DC transformer purchased from CMP is required to activate the controller 2 Wires may be cr...