3.1.5 Plumbing the Waterfall
If multiple waterfalls are installed, a separate pump is recommended. This will also require a separate
suction line to be plumbed. The dedicated pump and suction should be plumbed with a minimum of 2”
schedule 40 pipe. Anti-Vortex suction covers must be used to prevent possible entrapment for each suction
line that will be used in the construction. It is recommended to mount the vortex covers 18” above the
bottom of the pool. A filter/strainer is also required between the pump and the waterfall in this plumbing
situation. Installations requiring more than 60 gallons per minute may require two or more filters to be
plumbed in parallel. A separate line with a 3-way valve must be used to balance the water between the water
falls. Figure 7 below, shows the plumbing of a single waterfall unit.
Figure 7: Mechanical plumbing design for the Brilliant Wonder’s waterfall.
NOTE: It is always recommended to plumb the Brilliant Wonders Waterfall with a rock trap(C) just
before the line reaches the wall.
SUCTION LINE
SEPARATE RETURN
TO POOL
ROCK TRAP
PO
O
L W
ALL
PUMP
3-WAY VALVE
FIL
TE
R
WF